My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
5852
>
2200 - Hazardous Waste Program
>
PR0538926
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/29/2020 4:45:52 PM
Creation date
5/29/2020 4:36:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0538926
PE
2220
FACILITY_ID
FA0007939
FACILITY_NAME
CBUSO dba Turner Road Vintners (West)
STREET_NUMBER
5852
Direction
W
STREET_NAME
TURNER
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02512001
CURRENT_STATUS
01
SITE_LOCATION
5852 W Turner Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U I N Environmental Health Department <br /> - couNTY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address : Date : <br /> CBUSO dba Turner Road Vintners (West) 5852 W Turner Rd , Lodi January 07 , 2020 <br /> Treatment, Transport and Disposal <br /> 206 HSC 25160.2(c)(2) Waste stream or generator not eligible to use consolidated manifesting procedure ❑ V OR o COS <br /> 207 HSC 25144.6(b) Failure to properly manage reusable soiled textile materials ❑ V ❑ R o COS <br /> 208 HSC 25200.3. 1 (c) Failure of laboratory to comply with hazardous waste treatment requirements o V o R ❑ COS <br /> 209 CCR 66262.34(d )(2) I Failure to remove all hazardous waste from tanks , containers and containment upon facility closure o V o R o COS <br /> Preparedness and Prevention <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste ❑ V ❑ R ❑ COS <br /> 302 CCR 66262.34 (d)(2) Failed to maintain required emergency equipment ❑ V n R n COS <br /> 303 CCR 66262. 34(d)(2) Failed to maintain all communication or alarm systems , spill control, or decontamination equipment ❑ V o R o COS <br /> 304 CCR 66262.34(d )(2) Failed to maintain adequate aisle space for unobstructed response to emergencies ❑ V o R ❑ COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition o V OR ❑ COS <br /> 402 CCR 66262 . 34 (d )(2) Failed to store hazardous waste in a compatible container ❑ V ❑ R ❑ COS <br /> 403 CCR 66262.34(d )(2 ) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste o V OR o COS <br /> 404 CCR 66262.34(d )(2) Failed to inspect hazardous waste storage areas at least weekly ❑ V ❑ R o COS <br /> 405 CCR 66262.34(d )(2) Failed to manage incompatible wastes in containers properly ❑ V ❑ R ❑ COS <br /> 406 CCR 66261 .7 Contaminated container not marked with date emptied or managed within one year of being emptied ❑ V ❑ R o COS <br /> 407 CCR 66262 .34(e)( 1 )(A) Satellite accumulation container not located near point of generation or under control of operator o V ❑ R o COS <br /> 408 CCR 66262. 34(e)(2 ) Satellite accumulation exceeded 55 gallons of HW (or one quart of acutely HW) per waste stream o V o R o COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank o V o R ❑ COS <br /> 502 CCR 66262.34 (d )(2) Tank system inspections of discharge systems , monitoring equipment, and tank levels not done daily o V o R ❑ COS <br /> 503 CCR 66262 .34 (d )(2) Tank system inspections of construction materials, fixtures, and surrounding areas not done weekly ❑ V ❑ R o COS <br /> 504 CCR 66262 .34 (d )(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment n V ❑ R o COS <br /> 505 CCR 66262 .34(f) Failed to completely label stationary hazardous waste tanks n V ❑ R ❑ COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(d ) Stored hazardous waste onsite greater than 180 days ❑ V ❑ R ❑ COS <br /> 602 CCR 66262.34(e )( 1 )(B ) Stored satellite accumulated waste on site longer than one year or 180 days after fill date ❑ V ❑ R o COS <br /> 603 CCR 66262.34 (e)( 1 )(C) Failed to mark initial accumulation start date on satellite containers ❑ V ❑ R o COS <br /> 604 CCR 66262 .34 (e)(3) Failed to mark satellite containers with date filled within three days o V o R ❑ COS <br /> 605 CCR 66262 . 34 (f) Failed to completely label containers or portable tanks of hazardous waste o V o R ❑ COS <br /> 606 CCR 66266 .81 (a )(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V ❑ R ❑ COS <br /> 607 CCR 66266.81 (b) Damaged lead acid batteries not properly managed and labeled o V o R ❑ COS <br /> 608 CCR 66266. 130 Failed to properly manage used oil and fuel filters o V o R o COS <br /> 609 HSC 25143 .2, 25143.9 Failed to meet requirements for claimed excluded recyclable materials ❑ V ❑ R ❑ COS <br /> FA0007939 PRO538926 SCO01 01 /07/2020 <br /> EHD 22-01 Rev. 9/20/2019 Page 2 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.