My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2717
>
2200 - Hazardous Waste Program
>
PR0539090
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2020 11:08:09 AM
Creation date
6/1/2020 8:59:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0539090
PE
2220
FACILITY_ID
FA0010035
FACILITY_NAME
MARTIN OPERATING PARTNERSHIP LP
STREET_NUMBER
2717
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503001
CURRENT_STATUS
01
SITE_LOCATION
2717 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN,tIOAQUIN Environmental Health Department <br /> COUNTY— <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MARTIN OPERATING PARTNERSHIP LP 2717 W WASHINGTON ST, STOCKTON May 21, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days. <br /> OBSERVATION: The following hazardous waste containers were found on-site with an accumulation start date of <br /> greater than 180 days or no accumulation start date: <br /> One 55-gallon container of used antifreeze, partially full, with no hazardous waste label. <br /> One 55-gallon container of used oil which contained approximately 7 gallons, with no hazardous waste label. <br /> One 55-gallon container of used oil filters, not punctured, half full of filters, with no hazardous waste label. <br /> One 200-gallon tank of used oil which contained 40 gallons and had an accumulation start date of 12-1-18. <br /> REGULATION GUIDANCE.- <br /> (a) <br /> UIDANCE:(a) Except as provided in subsections (c) and (d) of this section and section 66262.35, a generator may accumulate <br /> hazardous waste on-site for 90 days or less without a permit or grant of interim status, provided that: <br /> (b) The beginning of the 90 day period specified in subsections (a) and (c) of this section is determined as follows: <br /> (1) if the generator does not generate more than 100 kilograms of hazardous waste or one kilogram of acutely <br /> hazardous waste (listed in section 66261.33(e))or one kilogram of extremely hazardous waste during any calendar <br /> month, the 90 day period begins on the date the generator has accumulated 100 kilograms of hazardous waste or <br /> one kilogram of acutely hazardous waste or one kilogram of extremely hazardous waste; <br /> (2) if the generator generates more than 100 kilograms of hazardous waste or one kilogram of acutely hazardous <br /> waste or one kilogram of extremely hazardous waste during any calendar month, the 90-day period begins on the <br /> first date on which any amount of hazardous waste begins to accumulate during that month. <br /> (d) Notwithstanding subsections (a) and (c) of this section and section 66262.35, a generator of less than 1,000 <br /> kilograms of hazardous waste in any calendar month who accumulates hazardous waste onsite for 180 days or <br /> less, or 270 days or less if the generator transports the generator's own waste, or offers the generator's waste for <br /> transportation, over a distance of 200 miles or more, for offsite treatment, storage, or disposal, is not a storage <br /> facility if all of the following apply: <br /> (1) The quantity of hazardous waste accumulated onsite never exceeds 6,000 kilograms. <br /> (2) The generator complies with the requirements of 40 Code of Federal Regulations section 262.34(d), (e) and (f). <br /> (3) The generator does not hold acutely hazardous waste or extremely hazardous waste in an amount greater than <br /> one kilogram for more than 90 days. <br /> CORRECTIVE ACTION: Immediately dispose of the hazardous waste stored on site greater than 180 days in <br /> compliance with Title 22 California Code of Regulations. Provide a corrective action statement and a copy of the <br /> disposal records to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> FA0010035 PRO539090 SCO01 05/21/2020 <br /> EHD 22-01 Rev.9/20/2019 Page 5 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.