Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PLAZA LIQUOR#1 T800 S CHEROKEE LN, LODI March 16, 2020 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 105 CCR 2632(d)(1), 2634(d)Failed to have an approved UST monitoring plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> -UDC leak sensor manufacturer and model were left blank on the monitoring plans for all tanks. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> OBSERVATION:Annual monitoring system certification, leak detector testing, and spill container testing was <br /> performed on 3/26/2019 and a test report was submitted on 5/24/2019, 1 month late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a repeat violation, Class II. <br /> 201 CCR 2712(b)(1-2)Failure to maintain monitoring, maintenance, and follow up action records. <br /> OBSERVATION: The following maintenance and monitoring records were not found on site. <br /> -2018 Monitoring System Certification Report <br /> -2018 Secondary Containment Test Report <br /> -2019 Overfill Prevention Equipment Inspection Report <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration and maintenance <br /> records; (3)results of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs <br /> of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6)results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br /> last three years on site and submit copies to the EHD. <br /> This is a Class II violation. <br /> FA0003997 PR0231325 SCO01 03/16/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />