My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
V
>
VIA NICOLO
>
17950
>
2900 - Site Mitigation Program
>
PR0516772
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2020 12:35:35 PM
Creation date
6/1/2020 12:29:36 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0516772
PE
2965
FACILITY_ID
FA0012793
FACILITY_NAME
MUSCO OLIVE LAND APP/TITLE 27
STREET_NUMBER
17950
Direction
W
STREET_NAME
VIA NICOLO
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20911032
CURRENT_STATUS
01
SITE_LOCATION
17950 W VIA NICOLO RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> J <br /> Kennedy/Jenks Consultants <br /> 3. Tum on meter and immerse pH and temperature probe in a pH 7 buffer solution. Calibrate <br /> meter to pH 7, allowing enough time for meter to stabilize. <br /> 4. Rinse pH and temperature probe with DI water. <br /> 5. Immerse pH and temperature probe in either a pH 4 or a pH 10 buffer solution, depending on <br /> whether expected pH of samples is above or below pH 7. If expected sample pH is above pH 7, <br /> use pH 10 solution for the second calibration. If expected sample pH is below pH 7, use pH 4 <br /> for the second calibration. Calibrate meter to second pH solution, allowing enough time for <br /> meter to stabilize. <br /> 6. Rinse pH and temperature probe with DI water. <br /> 7. Perform occasional rechecking of meter calibration to pH 7 calibration solution during usage. <br /> Repeat the calibration process (Steps 2-4) if value for final pH check is more than 0.1 units from <br /> pH 7.0. <br /> 8. Immerse the EC probe in EC solution of known conductivity. Calibrate according to <br /> manufacturer's instructions. <br /> F.5 Maintenance <br /> 1. Store meter in case with pH electrode immersed in a pH 7 buffer solution. <br /> 2. Inspect pH and temperature probes for cracks and scratches. <br /> 3. Inspect pH probe for containing adequate amount of KCI solution. If amount is low, refill as <br /> needed. <br /> 4. Carry spare batteries and screwdriver in the meter case. <br /> 5. Carry a copy of the instruction manual with meter. <br /> Appendix F Work Plan for Improved Detection Monitoring Program <br /> Page F-2 Musco Family Olive Company, Tracy, California <br /> g:VsymepledmhypE10MX104,00 mus welW+epMN 21ampleppeMimslappdx lAm <br />
The URL can be used to link to this page
Your browser does not support the video tag.