Laserfiche WebLink
'________________ ___ ------------------------------ <br /> FALLING HEAD PERMEABILITY TEST CONDITIONS DATA <br /> Cell No. : 6C Panel No. : 6 Positions: C <br /> ' Run Number: 1 2 <br /> ' Cell Pressure: 62 . 0 psi 0. 0 psi <br /> Inflow Saturation Pressure: 60. 0 psi <br /> 0. 3000 0. 0 pmt <br /> si <br /> Inflow Buret Area: 0 . 3000 cm <br /> Outflow Buret Area: 0. 3000 cm= 0. 3000 cm2 <br /> ' Test Temperature: 18 . 5 °C 0 . 0 °C <br /> ____ ----------------- <br /> PERMEABILITY TEST READINGS DATA <br /> CASE DATE TIME ELAPSED INFLOW OUTFLOW OUTFLOW/ PERM. PERM. / <br /> ' D X (24 hr) TIME LEVEL LEVEL INFLOW K RUNNING <br /> S sec cm cm RATIO cm/sec 4 AVE. <br /> ' S X 3/28/ 1 6: 08: 00 0 44 . 40 28 . 0 0. 00 0. 00E 00 0. 00 <br /> X 3/28/ 1 7 : 18: 00 4 , 200 44 . 20 28 . 2 1. 00 5. 47E-07 0. 00 <br /> X 3/28/ 1 10: 28: 00 11, 400 43 .80 28 . 8 1. 50 5. 27E-07 0. 00 <br /> 3/28/ 1 13 : 52 : 00 12 , 240 43 . 50 29. 3 1. 67 4 . 17E-07 0. 00 <br /> X 3/29/ 1 11: 12 : 00 76, 800 41. 50 31.5 1. 08 4 . 19E-07 0.88 <br /> 3/30/ 1 8: 56: 00 78, 240 40. 00 32 .9 0. 97 4 . 13E-07 0.93 <br /> ' 3/30/ 1 14 : 53 : 00 21, 420 39.70 33 . 2 1. 00 3 . 84E-07 0. 94 <br /> 3/30/ 1 20: 19 : 00 19 , 560 39 . 50 33 . 5 1. 50 3 . 81E-07 0. 95 <br /> Average differential head = 0.4 psi, 30. 8 cm H2O <br /> 'Gradient = 9 . 691E-01 Total vol = 1. 56E 00 cc Test duration = 223 , 860 sec <br /> Permeability, K18 .50 = 3 .986E-07 cm/sec, K200 = 4 . 135E-07 cm/sec <br /> Permeability values are incremental <br /> 1 <br /> DATA SET 156 <br /> PAGE 2 SIERRA TESTING <br /> --------------------------------------------------- <br />