Laserfiche WebLink
_______ _ ----------------------0----------------------- <br /> FALLING HEAD PERMEABILITY TEST CONDITIONS DATA <br /> Cell No. : 50 Panel No. : 5 Positions: C <br /> ' Run Number: 1 2 <br /> ' Cell Pressure: 62 . 0 psi 0. 0 psi <br /> Inflow Saturation Pressure: 60. 0 psi 2 0. 3000 psi <br /> Inflow Buret Area: 0. 3000 cm <br /> ' Outflow Buret Area: 0. 3000 cm2 0. 3000 cm2 <br /> Test Temperature: 18 . 5 °C 0. 0 °C <br /> ---------------- <br /> PERMEABILITY TEST READINGS DATA <br /> CASE DATE TIME ELAPSED INFLOW OUTFLOW OUTFLOW/ PERM. PERM. / <br /> ' D X (24 hr) TIME LEVEL LEVEL INFLOW K RUNNING <br /> S sec cm cm RATIO cm/sec 4 AVE. <br /> ' S X 3/28/ 1 6: 09: 00 0 73 . 60 31.9 0. 00 0. 00E 00 0. 00 <br /> X 3/28/ 1 7 : 18: 00 4, 140 73 . 50 32 . 0 1. 00 9 . 67E-08 0. 00 <br /> X 3/28/ 1 8: 30: 00 4, 320 73 .40 32 . 1 1. 00 9 . 31E-08 0.00 <br /> X 3/28/ 1 10:29 : 00 7, 140 73 . 20 32 . 3 1. 00 1. 13E-07 0. 00 <br /> 3/28/ 1 11: 50: 00 4, 860 73 . 10 32 .4 1. 00 8 . 40E-08 0.87 <br /> 3/28/ 1 13 : 02 : 00 4, 320 73 .00 32 . 5 1. 00 9. 49E-08 0. 99 <br /> X 3/29/ 1 6: 01: 00 61, 140 71.75 33 . 9 1. 12 9 .21E-08 0. 96 <br /> 3/29/ 1 7 : 57 : 00 6, 960 71. 60 34 . 1 1. 00 9 . 52E-08 1.04 <br /> 3/29/ 1 14 :46: 00 24,540 71. 10 34 . 6 1. 10 9. 62E-08 1.02 <br /> 'Average differential head = 0. 5 psi, 33 . 3 cm H2O <br /> Gradient = 3 . 792E 00 Total Vol = 7 . 80E-01 cc Test duration = 117 , 420 sec <br /> Permeability, K18. 5° = 9.257E-08 cm/sec, K200 = 9 . 604E-08 cm/sec <br /> 'Permeability values are incremental <br /> 1 <br /> PAGE 2SIERRA TESTINGDATA SET 155 <br />