_0_ ---------------- <br /> FALLING HEAD PERMEABILITY TEST CONDITIONS DATA <br /> Cell No. : 1B Panel No. : 1 Positions: B <br /> tRun Number: 1 2 <br /> ' Cell Pressure: 62 . 0 psi 0. 0 psi <br /> Inflow Saturation Pressure: 60. 0 psi 0 . 0 0. 3000 psi <br /> Inflow Buret Area: 0. 3000 cm2 <br /> ' Outflow Buret Area: 0. 3000 cm2 0. 3000 cm2 <br /> Test Temperature: 22 . 0 °C 0. 0 °C <br /> _ <br /> PERMEABILITY TEST TEST READINGS DATA <br /> CASE DATE TIME ELAPSED INFLOW OUTFLOW OUTFLOW/ PERM. PERM. / <br /> D X (24 hr) TIME LEVEL LEVEL IN-FLOW K RUNNIN( <br /> S sec cm cm RATIO cm/sec 4 AVE. <br /> ' S X 5/23/ 1 8 : 16: 00 60 75.50 12 . 2 0. 09 9 . 06E-05 0. 00 <br /> ' X 5/23/ 1 8: 17:00 60 72. 60 15. 3 1. 07 8.72E-05 0.00 <br /> X 5/23/ 1 8: 18: 00 60 70. 10 18 . 1 1. 12 8. 50E-05 0. 00 <br /> 5/23/ 1 8 : 19: 00 60 67 .70 20. 5 1. 00 8 .48E-05 0.98 <br /> 5/23/ 1 8: 20: 00 60 65. 60 22 .7 1. 05 8 . 36E-05 0.98 <br /> ' 5/23/ 1 8: 21: 00 60 63.70 24 .7 1. 05 8 . 34E-05 0.99 <br /> 5/23/ 1 8: 22 : 00 60 62. 00 26. 6 1. 12 8. 48E-05 1. 01 <br /> Average differential head = 0.0 psi, 0. 0 cm H2O <br /> ' Gradient = 8. 625E 00 Total vol = 5. 22E 00 cc Test duration = 420 sec <br /> Permeability, K22 .00 = 8.415E-05 cm/sec, K200 = 8 . 021E-05 cm/sec <br /> Permeability values are incremental <br /> ' <br /> PAGE <br /> ==2SIERRA-TESTING <br /> DATA-SET-206 <br />