Laserfiche WebLink
�- <br /> _ F <br /> "Y - <br /> =r <br /> 1 � <br /> San Joaquin local Health DiStrlct <br /> Re: Laura Scudders <br /> July 12, 1989 <br /> Page T+ao <br /> The inorganic lead analysis for T-1 East indicated a lead content <br /> of 61.3 ppm. The inorganic lead analysis for T-1 West indicated a lead <br /> content of 54.2 ppm. <br /> As a means of remediation and further data gathering, we propose <br /> to excavate to a depth of fifteen feet within, the confines of the <br /> existing excavation, approximately 8'W x 16% . Approximately nineteen <br /> yards of material will be removed in this process. All soils removed <br /> will be stockpiled in a secure area on a sheet of visqueen. The soil <br /> will then be covered with visqueen until disposal can be arranged. <br /> Two soil samples will men be extracted at the 15' depth by Ray <br /> F. Weston Labs. Additionally, one more sample will be extracted at <br /> a depth of 2' from under the existing asphalt cover approximately <br /> 50' frau the tank 1 pit. This sample will be to verify any existing <br /> background ?.evels of lead on the site. All samples will be analyzed <br /> for total inorganic lead content. <br /> Upon receipt of sample results a plan for further work will be <br /> submitted, or a request to ccmplete the closure. <br /> 3) Tank 3 Pipeline <br /> A 2" steel diesel fuel product line from tank W3 to the northwest <br /> corner of the truck stop was removed on May 30, 1989. She length of <br /> the product line was in excess of 200 feet. (See site map). Thirteen <br /> ;,.oil samples were collected by Roy F. Weston labs. All thirteen were <br /> collected at a depth of two feet below grade. All samples are identi- <br /> fied as P-1-P-12A as well as dispenser A, or P-l-P-12B and dispenser <br /> B. All "A" samples were analyzed using EPA standard 8020. All "B" <br /> samples were analyzed using EPA standard 8015 modified. <br /> Under the 8015 modified, only sample 12-B contained a total petro- <br /> leum hydrocarbon value. This value is 24 ppm. <br /> Under the 8020 standard, samples P2-A, P2-4, P7 A, P8-A, P9 A, <br /> P10 A, P11-A, P12-A and dispenser A indicate slight values for Tolulene. <br /> As a means of remediation and further data gathering we propose to <br /> - excavate the product line trench to a depth of four feet from grade. <br /> All excavated material will be stockpiled on visqueen in a secure area <br /> with a sheet of visqueen covering the soil. <br /> --� Five soil samples will be collected along the trench at the direction <br /> - - ---of a--San Joaquin_Incal Health District-representative.___All-samples <br /> -will_--- -_. _---- -- - _� -- <br /> be analyzed under EPA standard 8015 modified and 8020 by Roy F. Weston <br /> Labs. <br />