My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
720
>
2200 - Hazardous Waste Program
>
PR0514108
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 5:46:17 PM
Creation date
6/3/2020 9:21:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0514108
PE
2227
FACILITY_ID
FA0009957
FACILITY_NAME
Firestone Complete Auto Care #028746
STREET_NUMBER
720
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09402043
CURRENT_STATUS
01
SITE_LOCATION
720 E HAMMER LN STE 1
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2227_PR0514108_720 E HAMMER_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
494
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the tank. The pump discharges into the tank through a short length of 1" hose. Ball valves for <br />air supply to the pump and suction line isolation are located near the suction pipe. A 2" <br />galvanized steel vent line is run outside the building to a point above roof level. It is presumed <br />that the vent line terminates at a 90 degree elbow although this could not be confirmed to the <br />height of the roof parapet. The product removal line is a 1 '/2" dip tube in the tank. The product <br />removal port is capped with a galvanized steel stub. <br />2.2.4 Description of Any Internal and External Pumps <br />The external pump is an ARO Ingersoll Rand brand air operated double diaphragm unit with <br />suction and discharge ball check valves and is UL listed. The model number was not visible at <br />the time of the assessment. Apex was able to locate basic product information at <br />httr)://fluids.inaersoIIrand.com/diaphragm/. The pump appears to have been installed per <br />manufacturer's guidelines and is in good working condition. <br />2.2.5 Sketch or Drawing of Tank Including Dimensions <br />A sketch of the AST is provided in Attachment 1 of this report. Photos are provided in <br />Attachment 2 and manufacturer's documentation is provided in Attachment. <br />2.2.6 Foundation <br />The AST is situated indoors on the concrete floor of the grade -level automotive service center. <br />In the Engineer's opinion, the foundation is adequate to support the load of the full tank. <br />Because the AST is situated indoors in a heated building, it is not subject to frost heave. The <br />AST is located in a store at 720 E Hammer Lane, Stockton, California 95210. The Engineer <br />consulted the California Geological Survey - Alquist-Priolo Earthquake Fault Zones and verified <br />the AST is not located within a mapped seismic fault zone; therefore, no anchoring is required. <br />2.3 Documented Age of the Tank System <br />The facility had no records documenting the age of the tank system and as of the date of this <br />report, Apex was unable to identify any documentation of the age of the tank system. <br />2.4 Description and Evaluation of Any Leak Detection Equipment <br />There is no alarm or leak detection equipment associated with the John Dow Industries Model <br />AGS -285 waste oil AST. Detection of product in the secondary containment is by visual <br />observation through a 1" inspection port or 4" emergency vent at the left side of the tank. Daily <br />Above Ground Storage Tank Professional Engineer Certification Page 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.