My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
5000
>
2200 - Hazardous Waste Program
>
PR0513732
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 1:34:36 PM
Creation date
6/3/2020 9:22:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0513732
PE
2228
FACILITY_ID
FA0003907
FACILITY_NAME
PANELLA TRUCKING LLC
STREET_NUMBER
5000
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
14330001
CURRENT_STATUS
01
SITE_LOCATION
5000 E FREMONT ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2228_PR0513732_5000 E FREMONT_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
308
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VISUAL INSPECTION OF INTERIOR: NO FAILURE AS OF 9/26/08 <br />TANK PARAMETERS ON INSPECTION: IN USE W/USED OIL ENCLOSED NO LEAKAGE <br />TANK DRAWING: SEE PLOT PLAN AND VERTICAL VIEW ATTACHED <br />SECONDARY CONTAINMENT: 8" CONCRETE BLOCK WALL 24" HIGH (SEE MATHCAD CALS ATTACHED) <br />CONTAINMENT IS NOT LINED OR COATED CONTAINMENT GREATER THAN 110% OF LARGEST TANK <br />CONTAINMENT CONDITIONS: VERY GOOD, NO CRACKS OR VOIDS <br />SEISMIC LOAD CALC. 1997 CBC: SEE ATTACHED MATHCAD CALS. ATTACHED <br />EXCEEDS SEISMIC REQUIREMENTS <br />TANK INTEGRITY TEST: VISUAL INSPECTION OF ALL AREAS OF THIS ABOVE GROUND STORAGE <br />TANK - NO LEAKS FOUND OR EVIDENCE OF A PREVIOUS LEAK <br />FIVE PSI PRESSURE TEST DONE ON 9/26/08 <br />PRODUCT IN TANK: 2' OF USED OIL <br />PROCEDURE: TANK VENT WAS REMOVED AND REPLACED WITH PLUG AND 0 TO 15 PSI GAUGE W/ VALVE <br />TANK ACCESS COVER WAS REMOVED AND A NEW GASKET AND BOLTS INSTALLED. TANK FILL LEVEL SYSTEM <br />WAS REMOVED AND PLUGGED. TANK FILL LINE AND PUMP WERE DISCONNECTED AND PLUGGED. AIR WAS <br />APPLIED THOUGH SCHROEDER VALVE. CHECKED FOR AIR LEAKS WITH SOAP SOLUTION. <br />LEAKS: AIR LEAK IN VENT PLUG, GASKET LEAK IN ACCESS COVER, TIGHTEN BOTH, AND RE -CHECK, OK. <br />RETURN TANK TO SERVICE: REINSTALL VENT AND FILL LEVEL MEASURING SYSTEM, INSTALL PUMP PIPING <br />EQUIPMENT: PRESSURE GAUGE 0 TO 15 PSI IN TENTH OF A POUND GRADUATION <br />TIME <br />PRESSURE <br />TEMP. DEG. F <br />12:30 PM <br />0.0 <br />93.6 <br />01:00 PM <br />5.0 <br />94.3 <br />01:25 PM <br />5.0 <br />94.3 <br />02:05 PM <br />5.0 <br />94.8 <br />02:15 PM <br />5.0 <br />94.5 <br />02:30 PM <br />5.0 <br />93.6 <br />02:45 PM <br />5.0 <br />93.2 <br />03:00 PM <br />5.0 <br />92.8 <br />03:15 PM <br />5.0 <br />93.0 <br />NOTES <br />START SLOW PRESSURE BUILD <br />AIR LEAK AT ACCESS COVER <br />03:30 PM 5.0 93.0 NO LEAKS NO TANK FRACTURES <br />TEST COMPLETE <br />PRESSURE ON BOTTOM OF TANK WITH 2' OF PRODUCT AND 5.0 PSI AIR PRESSURE 5.75 PSI <br />TANK FILL PIPING AND VACCUM PUMP rev 1/6/09 <br />TANK PIPING TESTED: OUTLET PIPING TESTED WITH THE TANK AT +5 PSI, SAME AS TANK. <br />PUMP AND FILL PIPING: HAS FREE DISCHARGE TO TOP OF TANK AND NOT UNDER WASTE OIL PRESSURE. <br />PUMP, FILL PIPING, AND HOSE WAS NOT PRESSURE TESTED DUE TO FREE DISCHARGE TO TANK. <br />PUMP, FILL PIPING, AND HOSE WAS DISCONNECTED DURING TANK TEST AS WAS THE FILL LEVEL GAUGE <br />THERE IS NO EVIDENCE OF ANY LEAKAGE, CRACKS, OR EVIDENCE OF WEAK POINTS IN THE SYSTEM. <br />NOTE: VACCUM PUMP AND FILL PIPING, WHEN OPERATING, HOLD LESS THAN 2 GALS OF USED OIL. <br />PAGE 2 <br />
The URL can be used to link to this page