Laserfiche WebLink
• <br />SKJOAQUIN <br />COUNTY <br />• <br />Environmental Health Department <br />Laruantity Hazardous Waste Generator Insp coon Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SWIFT TRANSPORTATION <br />901 D ARCY PKWY, LATHROP <br />July 09, 2018 <br />. SUMN4RY.OF VIOLATIONS` z< <br />�, <br />£ <br />CLASS 1, CLASS II, or MINOR , Notice to corn <br />Item # <br />Remarks <br />512 <br />CCR 66265.192(h) Failure to obtain an assessment or reassessment of a hazardous waste tank system. <br />Facility does not have a current tank assessment for the 1500 gallon used oil tank. The last available tank <br />assessment was dated May 11, 2011. The owner or operator of a hazardous waste tank shall obtain a written <br />assessment reviewed and certified by an independent, qualified, professional engineer, registered in California <br />attesting that the system has sufficient structural integrity, is acceptable for the transferring, storing, and treating of <br />hazardous waste, and that the tanks and containment system are suitably designed. Immediately have an <br />assessment prepared for the 1500 gallon used oil tank. Submit a schedule showing when this will be accomplished <br />to the EHD. <br />This is a Class II violation. <br />601 <br />CCR 66262.34(a) Stored hazardous waste on site longer than 90 days without a permit or authorization. <br />A white plastic portable tank of used antifreeze located outside the east side of the shop was observed with an <br />accumulation start date of 2/16/18. All hazardous waste containers shall be marked with the following information: <br />- the words "Hazardous Waste" <br />- name and address of generator <br />- hazardous properties <br />- physical state <br />- composition (contents) <br />- accumulation start date <br />Immediately label these containers and ensure that all containers are marked with all the required information. <br />Since these containers have been on site longer than 90 days, immediately contact a licensed hazardous waste <br />hauler to dispose of this waste under manifest and submit a copy of the manifest to the EHD. <br />This is a Class II violation. <br />605 <br />CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br />-A black metal 55 gallon drum of used paper filters was observed in the storage area on the outside of the east side <br />of shop without an accumulation start date. <br />-A black metal 55 gallon drum of used metal filters was observed in the storage area on the outside of the east side <br />of the shop without an accumulation start date. <br />All hazardous waste containers shall be marked with the following information: <br />- the words "Hazardous Waste" <br />- name and address of generator <br />- hazardous properties <br />- physical state <br />- composition (contents) <br />- accumulation start date <br />Immediately label these containers and ensure that all hazardous waste containers are marked with all the required <br />information. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />FA0012399 PR0515964 SCO01 07/09/2018 <br />EHD 22-02 Rev. 10/31/2017 Page 5 of 6 Large Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />