My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOLMAN
>
6441
>
2200 - Hazardous Waste Program
>
PR0514322
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 8:12:20 AM
Creation date
6/3/2020 9:23:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0514322
PE
2229
FACILITY_ID
FA0010424
FACILITY_NAME
CHASE CHEVROLET
STREET_NUMBER
6441
STREET_NAME
HOLMAN
STREET_TYPE
RD
City
STOCKTON
Zip
95212
CURRENT_STATUS
01
SITE_LOCATION
6441 HOLMAN RD
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2229_PR0514322_6441 HOLMAN_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aw <br /> P <br /> sp"111 Prevention Compliance Corpgration <br /> P.O.Box 1289........Waterford, CA 95386 Telephone: (209)969-0851 <br /> Email: spcco shot uil,cc�rt� <br /> Website: www.spcplan.com <br /> Certified Assessment Form E)for AST Systems <br /> Assessor: Spili Prevention Compliance Corporation Onsite Assessor:Todd McWhorter <br /> P.O.Box 1289 Telephone: (209)969-0851 <br /> Waterford,CA 95386 email: sjRccorpkhotmail.com <br /> Client: Chase Chevrolet Contact Person: Alex Robinson, Service Mgr. <br /> Address 6441 Holman Rd Phone Number: 209475-6640 <br /> City/State/Zip! Stockton CA 95212 Date of Test. -18-15 <br /> Assessment Data-Waste Coolant AST-a <br /> 1. AST Configuration &age of AST Horizontal AST Single wall steeVapprox 20 yrs old( Title 22 6130110 1 <br /> 1 a;Useful Life Remaining of AST AST has anproximatell 20 years of remaining life (Subsection k141 0) <br /> 2. AST Primary vessel construction(describe) 120 gals/Waste Coolan not leegible IUL142-Container/ <br /> Made to UL 142 construction standard-at least.093in.steel thickness per ITL Std.- <br /> 3. AST piping(describe)_l_in.galvanized Rine to 1 in.copper piping from top of AST to Graco Husky pumps <br /> approx 175 ft from nearest pump(1 of 1) <br /> 4. Inte al/Extemal pump description external Graco uskv 1040 pumps w/2 solenoid 12volt-10-200 si-w/tank <br /> monito -007 Solenoid)-External pump,which pumps waste coolant from service area to AST (see Ric) <br /> S. AST drawing(provided/drawn: source)__Lsee attached <br /> 6. Design Standard(ASME, UL,,etc.) UL 142 Si le Wall Steel Horiz.Rectangular design/Mfr: Lube Cube <br /> 7. AST foundation(describe) concrete sub-floor,Base of AST under UL 142 adequate to withstand the load of <br /> a full tank-Tank is anchored to wail with earthquake straps secured by 3/8 alien bolts into cinder block wall. <br /> 8. AST anchoring(seismic zone/floatation ride)AST is anchored to wall with tgrftuake straps]held into wall <br /> with 3/8 in.alien bolts into the cinder block wall,. Stockton is a(ground shaking)seismic region, but the <br /> AST is unlikely to move outside the steel berm and enclosure in a seismic event,nor is a risk of flotation in <br /> such an event. The AST is situated in a secured and covered enclosure. <br /> 9. AST will withstand frost-heave XX Yes No AST sits in secured lubricants enclosure. <br /> 10.AST previously relocated? Yes XX No <br /> 11.AST Corrosion Protection Tank is completelcovered in paint,compatible to steel berm. Tank has no <br /> specific corrosion protection beyond the paint. No part of the AST touches the ground. The base of the AST <br /> is steel,raising the AST 1 inch above the berm floor. There is no evidence of corrosiontaking place. Tank's <br /> construction material is carbon steel. AST sits in enclosure under roof,avoiding rainwater issues, <br /> 12.AST Spill Prevention Equipment Product generally not handled outside of its intended containers. <br /> Product removal occurs via pumping out thru a 6 in.flapper opening on top of AST. AST'sits in a berm <br /> designed to capture,for recovery,any spilled product.. <br /> 13. Overfill Protection: AST has BJ-007 alarm system designed to onerate 090%fill level. Alarm is both <br /> audible and visible with strobe light. Alarms operate in concert with 007 shut down systems,atyumps. <br /> 14.Toxic Considerations: Antifreeze is toxic to humans and animals.Waste antifreeze contains heavy metals <br /> such as lead,cadmium,and chromium in high enough levels to potentially make it a regulated hazardous <br />
The URL can be used to link to this page
Your browser does not support the video tag.