My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
835
>
2200 - Hazardous Waste Program
>
PR0220087
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 6:42:11 AM
Creation date
6/3/2020 9:23:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0220087
PE
2248
FACILITY_ID
FA0000541
FACILITY_NAME
PACIFIC COAST PRODUCERS*
STREET_NUMBER
835
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
LODI
Zip
95240
APN
N/A
CURRENT_STATUS
02
SITE_LOCATION
835 S STOCKTON ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2248_PR0220087_835 S STOCKTON_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
371
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(Section 66262.34) <br />Has the generator obtained and kept on file at <br />the facility a written assessment revi- <br />+.- e• <br />certified by an engineer in accordance with <br />section 66270.11(d) by: (66265.191(a)-) <br />(1) January 12, 1988 for tanks containing RCRA <br />HW, unless the generator is a conditionally <br />exempt SQG per 40 CER 261.5 or a 5W per <br />40 CFR 265.201? or <br />1992, for tanks containing only <br />non-RCRA HW, and tanks containing RCRA HW if <br />genexator is a conditionally exempt SQG per <br />40 CFR 261.5 or a SQG per 40 CFR 265.201?, or <br />If the tank stores waste that became hazardous <br />after the above dates, within 12 months of da <br />that the waste becomes a hazardous waste? <br />(66265.191 (c) ) <br />Faid the assessment consider all required <br />information, including: [66265.191(b)-] <br />(1) Original design standard(s)? <br />(2) HW characteristics? <br />(3) Existing corrosion protection? <br />(4) Documented age of tank, if known? <br />(5) Results of leak test, internal <br />inspection, or other tank examination? <br />If assessment conducted for 66265.191(a) found <br />that the tank is leaking or unfit for use, did <br />the generator ccaply with 66265.196 (see <br />page 9)? (66265.191(d)] <br />Desim and installation- of new tank system-.: <br />Has the generator obtained and kept on file at <br />the facility a written assessment reviewed and <br />Certified by an engineer in accordance with <br />section 66270.11(d) prior to placing the tank <br />sYsteM in service? (66265.192(a)) <br />a 1�11 I V I <br />M4VQ—PW#M IOW IRWON, <br />(1) Original design standard(s)? <br />(2) HW characteristics? <br />(3) Factors affecting corrosion and needed <br />exterrk,.l corrosion protection? <br />(4) Protection against vehicular traffic if an <br />underground tank? <br />(5) Foundation strength, anchoring, and frost <br />heave protection? <br />Revised 7/15/91 Page 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.