My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
835
>
2200 - Hazardous Waste Program
>
PR0220087
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 6:42:11 AM
Creation date
6/3/2020 9:23:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0220087
PE
2248
FACILITY_ID
FA0000541
FACILITY_NAME
PACIFIC COAST PRODUCERS*
STREET_NUMBER
835
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
LODI
Zip
95240
APN
N/A
CURRENT_STATUS
02
SITE_LOCATION
835 S STOCKTON ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\HW\HW_2248_PR0220087_835 S STOCKTON_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
371
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />11 <br />57 66265.195(a) Failed to conduct daily inspection of tanks for <br />following: discharge control equipment, corrosion, releases, <br />monitoring and leak detection data, construction materials and <br />secondary containment areas, and level of waste in uncovered tanks. <br />(GOR) <br />58 66265.195(b) Failed to inspect cathodic protection systems (if <br />present) and sources of impressed current as appropriate. (GOR) <br />59 66265.196 Failed to remove from service immediately a tank system or <br />secondary containment system that had leaked or spilled. (GOR) <br />60 66265.197 During closure of tank system, failed to remove or <br />decontaminate all waste residues, contaminated tank system, soils, and <br />manage them as HW. (GOR) <br />61 66265.198(a) Stored or treated in tanks ignitable or reactive waste so <br />as to cause the waste to ignite or react. (GOR) <br />62 66265.198(b) Failed to comply withbufferzone requirements for tanks <br />containing ignitable or reactive wastes per NFPA "Flammable and <br />Combustible Liquids Code. (GOR) <br />63 66265.199(a) Stored incompatible wastes in same tank without complying <br />with 66251.17(b). (GOR) <br />64 66265.199(b) Placed HW in non -decontaminated tanks that previously <br />held an incompatible waste or material without complying with <br />66251.17(b). (GOR) <br />Ignitable, Reactive, or Incompatible Wastes <br />NOTE: The following requirement applies to generators per <br />66265.177(a) for containers and 66265.199(a)&(b) for tanks. <br />65 66265.17(b) Failed to conduct transfer, storage, treatment, or <br />disposal of ignitable or reactive wastes / mixture or commingling of <br />incompatible wastes/materials to prevent: <br />(1) Generation of extreme heat or pressure, fire or explosion, <br />or violent reaction. <br />(2) Production of uncontrolled toxic mists, fumes, dusts or <br />gases to threaten human health or environment. <br />(3) Production of uncontrolled flammable fumes or gases to pose <br />risk of fire or explosions. <br />(4) Damage to structural integrity of HW containment devices. <br />(5) Threat to human health or the environment. (GOR) <br />0 <br />