My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30131
>
2300 - Underground Storage Tank Program
>
PR0231737
>
COMPLIANCE INFO_1995-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 5:33:55 PM
Creation date
6/3/2020 9:42:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2011
RECORD_ID
PR0231737
PE
2332
FACILITY_ID
FA0003922
FACILITY_NAME
CEMEX Construction Materials Pacific, LLC
STREET_NUMBER
30131
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
Dr
City
Tracy
Zip
95377
APN
25313011
CURRENT_STATUS
04
SITE_LOCATION
30131 S MacArthur Dr
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231737_30131 S MACARTHUR_1995-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> 6g Ncg <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD , <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM Bp; <br /> •c,IIPORN�'` <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ® 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ® 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 'C <br /> I. TANK DESCRIPMON COMPLETE ALL ITEMS- SPE IFY IF UNKNOWN <br /> A. OWNERS TANK 1.D.# ,Jw B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) L n D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A ❑ 9 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. Lj to REGULAR UNLMED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ® 2 PETROLEUM ® 80 EMPTY 1 PRODUCT ❑ lb PREMIUM UNLEADED ® 4 GASAHOL ❑ 7 METHANOL <br /> ® tc M E UNLEADED 5 JET FUEL ❑ 8 M85 <br /> 3 CHEMICAL PRODUCT ® 95 UNKNOWN ® 2 WASTE ❑ 2 LEADED H 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A1)IS NOT ,ENTER NAME OF SUBSTANCE STORED �` f� C.A.S.#: 5 %Z/ <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN SORES A,B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ i DOUBLE WALL ® 3 SINGLE WALL WITH EXTERIOR UNER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ® 3 FIBERGLASS ® 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ® 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FR® <br /> ftimity Tank) ® 9 BRONZE ❑ 10 GALVANIZED STEEL ® 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ® 2 ALKYD LINING ® 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 6 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ® 3 VINYL WRAP ® 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONEEj?L95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL,et0 SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO STRIKER PLATE YES NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 9 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A 99 OTHER <br /> B. CONSTRUCTION Ao 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL coMPAnBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION 95 UNKNOWN A U 99 OTHER <br /> 1 CAL L LEAK 2 Ufa 70MESS 3 4 LINE <br /> 5 AUTOMATIC PUMP <br /> D. LEAK DETECTION ❑ DETECMR ❑ TESnNa ® ® exAK cTOR ® SHUTDOWN E] as DITHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ® 2 RREECCOUNNCWIIATIIONORY ❑ 3 V MONITORING ® 4 GAUGINAUTOMATIC TANK ❑5 MONITORINGROUND WATER 716 TESTINGNUAL TANK <br /> ® 7 CO NSU US INTERSTITIAL [18 SIR ❑ 9 WEEKLYA UGINQ MANUAL ®10,M�OSNTHLLY TANK 95 UNKNOWN ®99 OTHER <br /> ING TANKVI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATE DAUE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF3.WAS TANK FILLED WITH <br /> t f SUBSTANCE REMAINING S' GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNERS NAME - ov FORDATE <br /> (PRINTED&SKINATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.4 m I I 1 1 Tu <br /> PERMIT NUMBERPERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE Li -- I <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORMA HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLO N. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENITING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORMS (695) <br />
The URL can be used to link to this page
Your browser does not support the video tag.