My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_1991-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 2:40:48 PM
Creation date
6/3/2020 9:42:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2000
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1991-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P ti. <br /> STATE OF CALIFORNIA ' <br /> STATE WATER RESOURCES CONTROL BOARD .� <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION -FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION <br /> ❑;7PERMANE;NTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ NK REVEDG" <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: qr k <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN B MANUFACTURED BY. <br /> A. OWNER'S TANK I.D.A m—0 <br /> D. TANK CAPACITY IN GALLONS: <br /> C. DATE INSTALLED(MO/DAY/YEAR) <br /> 11.TANK,CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. ❑ iaREGULAR ❑ 3 DIESEL ❑ 6 AVIATIONGAS <br /> C <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> A. 1 <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY ❑PRODUCT ib PREMIUM UNLEADED ❑ '. JET FUEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,8,AND C.AND ALLTHAT APPLIES IN BOX D <br /> V <br /> DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> A. TYPE OF ❑ ss OTHER <br /> SYSTEM SINGLE WALL 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ <br /> ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> 8. TANK 6 POLYVINYL CHLORIDE 7 ALUMINUM ❑ 8 100'/ METHANOL COMPATIBLE W/FRP <br /> MATERIAL ❑ s CONCRETE ❑ <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 6 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 5 GLASS LINING <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO <br /> -- <br /> ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ?/VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> D.CORROSION L—iY9�5 UNKNOWN ❑ 99 OTHER <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 9/ NONE is <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> FCC. M TYPE <br /> �Al CTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> RUCTION NGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A(U 5 UNKNOWN A U 99 OTHER <br /> IAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> OSION A U 5 ALUMINUM p U 6 CONCRETE A U 7 ST Ej-W/COATING A U 6 100°/ METHANOL COMPATIBLE W/FFP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION U UNKNOWN p U 99 OTHER <br /> A <br /> D. LEAK DETECTION ❑ <br /> 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ MONIT?INTERSTITIORINGL ❑99 OTHER_ <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION3.WAS TANK FILLED WITH YES Gl NO ❑ <br /> ::::�SUB�STANCE <br /> UANTITY OF GALLONS INERT MATERIAL? <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) REMAINING <br /> THISFORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE E IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRINTED 8 SIGNATURE) <br /> LOCAL AGENCY USE QNLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW TANK# ¢L L <br /> COUNTY# JURISD�ICTI❑ON# FACILM# qGSTATE I.D.# Ld .3 r <br /> PERMIT NUMBER <br /> PERMIT APPROVED BY/DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION.FORMA,UNLLEE�S ENT FORMA HAS BEEN FILED� � FOROMB R4 <br /> FORM B (9-90) <br /> �/ L J ` ( 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.