My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_1991-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 2:40:48 PM
Creation date
6/3/2020 9:42:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2000
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1991-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DFAl <br /> CALIFORNIA 'ANNUAL STATISTICAL INVENTORY RECONCILIATION (SIR) SUMMARY REPORT <br /> County: SAN JOAQUIN Year: 1997 <br /> Facility Name: DFAS-COLUMBUS CENTER Owner: DFAS-COLUMBUS CENTER <br /> Address: City: LATHROP Zip: <br /> Tank I.D. 373 Capacity: 20000 Product: UNLEADED <br /> Last Tank Test / / Pass/Fail I Last Leak Detector Check / / Pass/Fail <br /> Last Piping Test / / Pass/Fail Last Meter Calib. Check / / Pass/Fail <br /> ® All monthly SIR results for the above mentioned tank at the above facility <br /> were "Pass" for the twelve month period from January 1997 to December 1997. <br /> Monthly SIR results showing "Fail" or "Inconclusive" occurred on the <br /> following months, in the listed amounts, for the above UST. If the SIR <br /> result for a month exceeded the SIR method's threshold or was "Inconclusive" <br /> appropriate corrective actions described in Section 2646. 1 must be taken. <br /> The local agency must be notified within 24 hours of receiving a "Failed" <br /> or "Inconclusive" SIR report. <br /> Summary of test results from monthly SIR reports. <br /> Minimum <br /> Leak Detectable Calculated Specify <br /> Threshold Leak Rate Leak Rate Pass,Fail Follow-up <br /> Month/Year (gph) (gph) (gph) Inconclusive Actions <br /> 1/1997 0. 10 0. 125 -0. 078 PASS <br /> 2/1997 0. 10 0. 118 -0. 090 PASS <br /> 3/1997 0. 10 0. 060 0. 110 INCONCLUSIVE <br /> 4/1997 0. 10 0. 100 -0. 070 PASS <br /> 5/1997 0. 10 0. 050 -0. 120 INCONCLUSIVE <br /> 6/1997 0. 10 0. 080 0. 010 PASS <br /> 7/1997 0. 10 0. 010 -0. 010 PASS <br /> 8/1997 0. 10 0. 150 0. 000 PASS <br /> 9/1997 0. 10 0. 030 -0. 010 PASS <br /> 10/1997 .0. 10 0. 050 0. 000 PASS <br /> 11/1997 0. 10 0. 070 0. 030 PASS <br /> 12/1997 0. 10 0. 150 0. 050 PASS <br /> SIR PROVIDER: USTMAN INDUSTRIES, INC. SIR VERSION: 94.2a <br /> 12265 W. BAYAUD AVE. <br /> SUITE 110 LAKEWOOD, CO 80228 <br /> PH: 303/986-8011 FAX: 3031986-8227 <br /> I certifyqhdaerpen:alty of e ;uryethat all SIR results listed above <br /> are a <br /> Signa(ye of Tank caner/Operator of Agent Date <br />