My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_1991-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 2:40:48 PM
Creation date
6/3/2020 9:42:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2000
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1991-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br />1. SITE MAP ENCLOSED WITH EQUIPMENT SHOWN/SPECIFIED. YES M NO [j <br />2. DESCRIPTION OF WORK TO BE COMPLETED: <br />#1 PRODUCT LINE FROM TANK #372(UNLEADED PUMP #2) TO ABOVE GROUND OVER- <br />HEAD FILL STATION. PIPE ISO INTEGRITY TESTING ONLY. <br />#2 PRODUCT LINE FROM TANK #372(UNLEADED PUMP #1) TO LOCATE LEAK <br />DETECT VALVES AND REPAIR, INSTALL AND RELOCATE AS NEEDED. <br />PIFE ISO INTEGRITY TESTING REQUIRED. <br />#3 PRODUCT LINE FROM TANK #373(UNLEADED TO DISPENSER #2) LOCATE LEAK <br />DETECT VALVES AND REPAIR, INSTALL AND RELOCATE AS NEEDED. ALSO <br />PERFORM PIPE ISO INTEGRITY TESTING. <br />#4 INSTALL 2 INSPECTION BOXES AND NON TRAFFIC LIDS OVER AREA XaZEE <br />LEAK DETECTORS WILL BE INSTALLED. IF NEEDED. POMECO 112-24 <br />ADDITIONAL PAGES MAY BE ATTACHED. <br />3. DESCRIPTION OF EQUIPMENT TO BE USED: <br />#1 RED JACKET ADAPTOR #38-72 AND OR BIG-FLOLEAK-#116--6',7 ADAPTOR <br />BOTH OF THESE ADAPTORS CAN BE INSTALLED INTO EXISTING SYSTEMS. <br />#2 RED JACKET QLD LEAK DETECTOR MODEL #116-o(o <br />#3_POMECO 112-24 SQUARE MANHOLE FRAME AND COVER IF NEEDED <br />4. ALL EQUIPMENT IS STATE CERTIFIED OR APPROVED. YES M NO [] <br />2 <br />