FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1991-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WNITORING SYSTE14 RE MNSE PLO <br />_ ill <br />Date: 20 April 1991 <br />Facility: Bldg. 330, DDRW Sharpe Site, Lathrop, CA. <br />Owner: Federal Government <br />Operator: Defense Logistic Agency <br />Defense Distribution Region West <br />Sharpe Site, Bldg.'330 <br />SUBJECT: Underground Storage Tanks - - <br />County <br />s• - <br />County Tank Nos. 52, 53, 54 <br />Sharpe Tank Nos. 330-1 330-2 330-3 <br />Tank Volume (gallons) 12000 12000 550 <br />Product Diesel,Diesel Waste oil <br />Monitoring Sta. Nos. 1, 1, 2 <br />The secondary containment system of subject tanks will be continuously <br />monitored by a Pollulert electronic monitor using liquid sensing probes set <br />to immediate response time. These electronic monitoring panels (station) <br />are located in building 330. <br />The electronic monitor will be tested daily by person designated by operator. <br />In the case of an alarm condition, the designated person will immediately <br />contact the Distribution Facility Maintenance Supervisor who will make <br />arrangements to remedy the situation causing the alarm condition. Remedies <br />will be'coordinated with: Engineering Division, Office of Contracting, and <br />Environmental Protection Office. And do a annual inspection and P.N. of the <br />three underground tanks by a qualified maintenance person. <br />In the case of an emergency ( e.g. spill),ial *911. Sharpe's fire <br />department will respond along with other members of the spill response team <br />if required by the incident on-site commander. They will prepare Run Report <br />describing the spill and the clean-up effort. <br />If response, repair, clean-up, and resumption of normal operations occurs <br />within 8 hours of initial alarm the incident will be recorded in an on-site <br />logbook. <br />If the response to the alarm condition cannot be rectified within 8 hours. <br />then notify Sharpe's Environmental Protection Office at Ext. 2093 and San <br />Joaquin County Public Health Service Environmental Health Division at <br />(209) 568-3440/3420. <br />Person or office allowed to authorize the aforementioned work are: <br />Name or Office <br />Fac. Eng.ADF Section <br />Fac. Eng. ADF Section <br />Office of Contracting <br />Position <br />Maintenance Mechanic <br />Section Foreman <br />Contracting Officer <br />Type of Work <br />Monitoring <br />Remedy Coordination <br />Contract for repair/remedy <br />Services <br />Environmental Protection Envir. Engr. or Coordinate Monitor and <br />Office "Envir. Specialist Reporting requirements with <br />'regulatory agencies <br />
The URL can be used to link to this page
Your browser does not support the video tag.