My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1991-2000
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROTH
>
850
>
2300 - Underground Storage Tank Program
>
PR0231898
>
COMPLIANCE INFO_1991-2000
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 2:40:48 PM
Creation date
6/3/2020 9:42:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1991-2000
RECORD_ID
PR0231898
PE
2332
FACILITY_ID
FA0003966
FACILITY_NAME
SHARPE SITE/DEF LOG AGENCY
STREET_NUMBER
850
Direction
E
STREET_NAME
ROTH
STREET_TYPE
RD
City
LATHROP
Zip
95330
APN
19802001
CURRENT_STATUS
02
SITE_LOCATION
850 E ROTH RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0231898_850 E ROTH_1991-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If <br />contamination is documented during closure, an Unauthorized Release Notification must be completed and submitted <br />within five (5) working days pursuant to California Health & Safety Code, Section 25295. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MIP1Il' UM NUMBER LOCATION OF SOIL SAMPLES <br />of SOIL SAMPLES <br />Sample every 20 lineal feet <br />< 1,000 <br />1 per Tank Fill OR Pump End of Tank <br />2 <br />1,000 - 10,000 <br />2 per Tank 1 at each End of Tank <br />11000 - 10,000 <br />> 10,000 <br />3 or More Ends and Middle OR generally <br />per Tank spaced along the length of the Tank <br />SLAB PRESENT IN TEE TANK PTT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in <br />order to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />PIPING SOIL SAMPLES <br />1 <br />Sample every 20 lineal feet <br />TANK & PIPING STOCX?U-E SAMPLES <br />2 <br />Samples every 50 cubic yards <br />SLAB PRESENT IN TEE TANK PTT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in <br />order to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />HENT fUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL <br />MINIMUM NLTlVMER of <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />• t rt.LES <br />11000 - 10,000 <br />SAMPLES <br />Center and Ends OR Sides of Tank <br />•t••From <br />> 10,000 <br />wall next to tank <br />Ends and Middle and generally spaced along <br />the length of the Tank <br />ends at soil/ groundwater <br />interface <br />From wall next to tank <br />ends at soiaZ <br />groundwater interface <br />SLAB PRESENT IN TEE TANK PTT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in <br />order to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />HENT fUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />< 1,000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />11000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced along <br />the length of the Tank <br />EH 23 047 (Revised 7/10/92) Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.