11919
>
2300 - Underground Storage Tank Program
>
PR0232509
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/21/2022 2:02:02 PM
Creation date
6/3/2020 9:43:11 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0232509
PE
2332
FACILITY_ID
FA0003731
FACILITY_NAME
PRECISSI FLYING SERVICE
STREET_NUMBER
11919
Direction
N
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
LODI
Zip
95242
APN
05902047
CURRENT_STATUS
04
SITE_LOCATION
11919 N LOWER SACRAMENTO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2332_PR0232509_11919 N LOWER SACRAMENTO_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
277
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� r <br /> MRUA VERIFICATION LABORATORY AN IS <br /> OXYGENATES <br /> TANK TANK TPH-G TPH D BTX&E CL HC TOTAL MTBE (MTBE MMU PCB <br /> TBA, , ICAP/ <br /> ## CONTENTS 8015 8015 8020 8010 LEAD 8020 DIPE <br /> ETRE, AES or 8270 <br /> 8260 8260 8260 8240 7420 8260 TAME) AA 8080 <br /> 8260 7421 8260 <br /> LEADED GAS X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X X <br /> UNK FUEL X X X X X <br /> PROD.OIL X X X <br /> CHLOR X <br /> SOLVENTS X X <br /> NONCHLOR X <br /> SOLVENTS X X <br /> WASTE\ <br /> USED OIL X X X X X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846,Third Edition. Those methods not found in SW <br /> 846 are specifically noted below. Refer to the"SWRCB LUFT;7ield Manual",Appendix D(B),Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel(gasoline and d-rsel). Refer to"Tri-Regional Board Staff Recommendations for <br /> Initial Evaluation and Investigation of UST's"for the waste and:motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL,STLC or Allo:ruble Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative meth. d. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline; GC/FID(5030)8015 mod or GCIMS 8260 <br /> TPH-D Total Petroleum Hydrocarbon,Diesel,G /RD,(3550),8015 mod or GC/MS 8260 <br /> . BTX&E Benzene,Toluene,Xylene&Ethyl Benzene,GC/PID 8020 or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon,GC/HSD 8010,GUMS 8240 or 8260 <br /> TOTAL LEAD Total lead,AA 7420, AA 7421 or ICF-AES 6010 <br /> OXYGENATES MTBE,ETBE,TAME,DIPE,&TBA GUMS 8260(For MTBE screen only you may use 8020) <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. <br /> Metals:Cadmium,Chromium III and N1,Lead,Zinc and Nickel. <br /> PCB Polychlorinated Biphenyls,GUMS 8270 or 8080 <br /> GC-FID Gas Chromatography,Flame Ionization Detection <br /> _ Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation,extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed <br /> columns;a packed column may be used as a"first cut"with"dirty"samples or once the hydrocarbons have been characterized and proper QA/QC <br /> is followed. <br /> For drinking water sources,EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the <br /> detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal contamination may require further analysis.EHD <br /> recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 3/15/02) Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.