Laserfiche WebLink
r <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 2 <br /> ABOVEGROUND PIPING <br /> UNDERGROUND PIPING <br /> SYSTEM TYPE ❑ 1 PRESSURE 2. SUCTION ❑ 3. GRAVITY ❑ 1. PRESSURE ❑ 2.SUCTION ❑ 3. GRAVITY <br /> CONSTRUCTION/ ��❑ff 1. SINGLE WALL 3. LINED TRENCH ❑99. OTHER ❑ 1. SINGLE WALL ❑95. UNKNOWN <br /> MANUFACTURER UQ 2. DOUBLE WALL ❑95. UNKNOWN ❑ 2. DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER MANUFACTURER <br /> ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL ❑ 1.BARE STEEL ❑ 6. FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑ 2. STAINLESS STEEL ❑ 7. GALVANIZED STEEL ❑2. STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> CORROSION <br /> PROTECTION 11 3. PLASTIC COMPATIBLE WITH CONTENTS ❑95. UNKNOWN ❑ 3. PLASTIC COMPATIBLE WITH CONTENTS ❑ S. FLEXIBLE(HDPE) C ❑99.OTHER <br /> 4. FIBERGLASS ❑ S. FLEXIBLE(HDPE) ❑99. OTHER ❑ 4. FIBERGLASS ❑ 9. CATHODIC PROTECTION ro 5 STEEL W/COATING ❑ 9 CATHODIC PROTECTION ❑ 5 STEEL W/COATING ❑95 UNKNOWN <br /> PIPIN(3�EAKGE'b'hGjFON(Cheoka�Uratep <br /> 7 <br /> �.,. <br /> UNDERGROUND PIPING - ABOVEGROUND PIPING <br /> SINGLE WALL PIPING <br /> SINGLE WALL PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): - <br /> ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUTOFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION;-AUDIBLE AND VISUAL ALARMS . <br /> ALARMS ❑ 2.MONTHLY 0.2 GPH TEST - <br /> ❑ 2. MONTHLY 0.2 GPH TEST ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS(Check all that apply): - <br /> CONVENTIONAL SUCTION SYSTEMS: - - <br /> ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> C15. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY - <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING - <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): - <br /> ❑ -9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8..DAILY VISUAL MONITORING _ <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) - <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING - - <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check aq that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> Elc. NO AUTO PUMP SHUT OFF ❑ c. NO AUTO PUMP SMUT OFF - - <br /> ❑ 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR ❑ 11.AUTOMATIC LEAK DETECTOR <br /> RESTRICTION - <br /> ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12:ANNUAL INTEGRITY TEST(0.1 GPH) <br /> STION/GRAVITY SYSTEM: SUCTION/GRAVITYSYSTEM: <br /> 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND,VISUAL <br /> VISUAL ALARMS ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WRHOUT FLOW SHUT OFF OR .❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) 1 ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK 1017. DAILY VISUAL CHECK <br /> VHF I)19PEttt GOF4AINMC�FI s, 4 <br /> DISPENSER CONTAINMENT ❑ 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4. DAILY VISUAL CHECK <br /> DATE INSTALLED ❑ 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS 6. NONE <br /> OL OWNERIOPERATOR SIGNATURE <br /> I certify that the information provided herein is to to the best of my knowledge_ <br /> SIGNAT OF ER/O RATO DATE A Z- <br /> NA OWNER/OPERATOR(pd t) CB S�I TITLE OF OOPE O R n (a E <br /> J <br /> 79rmilumber(For local use only) Permit Approved(For local use only) Permit Expiration Date(Forlocal use only) <br /> CUPAFORM(4/99) Formerly SWRCB Form B <br />