My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_1986-1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 1:21:59 PM
Creation date
6/3/2020 9:43:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1995
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_1986-1995.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HUNTER ENVIRONMENTAL SERVICES, INC. FINAL TEST RESULTS <br />18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 8-26-87 <br />FOUNTAIN VALLEY, CA 92708 <br />800-247-9014 800-247-2186 <br />CUSTOMER: SHELL LOCATION/IDENTIFICATION NO.: N/A <br />ADDRESS: 2575 Country Club <br />Stockton, CA <br />TEST RESULTS SUMMARY <br />LEAK LOKATOR RESULTS <br />SYSTEM TANK SIZE WATER LEVEL ALR <br />NO. PRODUCT GALLONS DIA/MATL INCHES INCHES GPH CONCLUSION RECOMMENDATIONS <br />1 Super 8000 95"/ST 0 155 + .044 Tight <br />2 Unleaded 5000 95"/ST 1 159 + .035 Tight <br />3 Regular 8000 9511/ST 0 147 -1.267 Leak <br />104 + .034 Tight <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />PRODUCT LINES - <br />HYDROSTATIC PRESSURE TEST RESULTS <br />LEAK <br />SYSTEM <br />NO. PRODUCT <br />TYPE OF <br />REMOTE <br />PUMP POUNDS <br />SUCTION APPLIED <br />POUNDS MINUTES PRODUCT PRODUCT <br />HELD HELD LOSS CC's LOSS GPH <br />CONCLUSION <br />/RESULT <br />TEST <br />LEVEL <br />CLOCK <br />DURATION <br />`"^-r <br />2 Unleaded <br />3 Regular. <br />-Red Jacket <br />Red Jacket <br />Red Jacket <br />50 <br />50 <br />50 <br />10 <br />10 <br />10 <br />Pass <br />Pass <br />Pass <br />NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br />DETAIL OF TEST RESULTS <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Tests Conducted and Certified By: Test Van No. 30 <br />Team Manager: R. Roessler <br />Tank Testing Specialist: S. Porras <br />TEST <br />TIME <br />LEAK <br />RATE <br />TEMPERATURE <br />ABSOLUTE <br />CHECK <br />SYSTEM <br />TEST <br />LEVEL <br />CLOCK <br />DURATION <br />COMPENSATION <br />LEAK RATE <br />TEST <br />NO. PRODUCT <br />N0. <br />(IN.) <br />STATE <br />(HR -MIN) <br />CC/DIV <br />CC/MIN <br />DELTA of CC/MIN <br />CC/MIN GPA. <br />Y/N <br />1 Super <br />1 <br />155 <br />12:06 <br />35 Min <br />1.18 <br />+ 7.48 <br />+.014 +4.66 <br />+ 2.82 +.044 <br />N <br />2 Unleaded <br />1 <br />159 <br />11:35 <br />26 Min <br />2.15 <br />+11.99 <br />+.007 +9.77 <br />+ 2.22 +.035 <br />N <br />+.040 <br />3 Regular <br />1 <br />147 <br />1:47 <br />21 Min <br />3.57 <br />-83.34 <br />-.012 -3.37 <br />-79.97 -1.267 <br />N <br />2 <br />104 <br />3:26 <br />46 Min <br />6.31 <br />+ 8.20 <br />+.018 +5.99 <br />+ 2.20 + .034 <br />N <br />*LEVEL - Inches from Tank Bottom to Test Level <br />ALR - Absolute Leak Rate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br />CONCLUSION - NFPA 329 criterion of +/- 0.05 GPA is used to certify tightness <br />CERTIFICATION <br />This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br />LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br />established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br />Tests Conducted and Certified By: Test Van No. 30 <br />Team Manager: R. Roessler <br />Tank Testing Specialist: S. Porras <br />
The URL can be used to link to this page
Your browser does not support the video tag.