My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_1986-1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 1:21:59 PM
Creation date
6/3/2020 9:43:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1995
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_1986-1995.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
430
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
System, Model X76S <br />Power: 115 VAC, 60Hz <br />Power Consumption: 100 VA <br />Operating Temperature: 32 to 165°F (0 to 75°C) <br />Dimensions: 9x9.5x4.2 in. (22.86x24.13x 10.67 cm) <br />Mounting: General purpose area; wall mount <br /><<m">*Approved: File J.I. 2N4ALAX <br />Annunciator Module <br />Field Sensor: Dry contact <br />Field Sensor Voltage: 115 VAC (supplied by X76S) <br />Number of inputs: One per module <br />fM Approved: File J.I. 2N4A1.AX <br />Intrinsically Safe Field Sensor <br />Interface Module X53 <br />Number of Inputs: Two per module <br />Sensors Voltage: 24 VDC, current limited <br />Sensors: Dry contact <br />Output Interface to Alarm Module: Relay contact; <br />normally open/normally closed; selectable <br />Power Consumption: 750 mW per input <br />Supply Voltage: 24 VDC from IS power supply <br /><:=M> Approved: File J.I. 2N4A1. AX <br />Power Supply IS . (Intrinsically Safe) <br />Power Input: 115 VAC <br />Output Voltage: 24 VDC <br />fM Approved: File J.I. 2N4A1.AX <br />i <br />Vapor Sensor, Model HV <br />Detection Method: Solid-state diffusion type <br />Detectable Gases: Hydrocarbons, gasoline, solvents, <br />carbon monoxide, methane, ammonia, sulfur dioxide, <br />hydrogen sulfide <br />Detectable Range: 0-100% LEL <br />Accuracy: ±5% <br />Response Time: Less than 15 sec. to 90% full scale <br />Sensitivity: 5 ppm <br />Sensor Life: 5 years minimum <br />Zero Drift: Less than 5% per year <br />Operating Temperature: —400 to 165°F (-400 to 75°C) <br />Electrical Classification: Class 1, Division 1, Groups B, C <br />and D; hazardous atmosphere <br />Cable Length: 25 feet; 3 -conductor, number 2b AWG <br />shielded; max. length 3,000 feet <br />UL Approved: File E100826 <br />Operating Temperature-, 0 225°F (-18 to 107°C) <br />Pressure: 50 psi maximum <br />Leads: 22 AWG <br />UL Approved: File E86797 <br />Tmk Leak Sensor, Model LS -7 For fiberglass tank <br />Housing Material: ABS <br />Mounting: %2" NPT with %11 THD and lock nut <br />Pressure: 150 psig at 70°F (210C) maximum <br />Liquid SpG:.70 minimum <br />Switch: <br />Type: Single pole, single throw N.C. <br />Ratir�- 10 VA, 110 to 240 VAC <br />Leads: 22 AWG <br />Approved: :. • <br />ModelReservoir Type Tank Leak Sensor, r <br />Reservoir: <br />Volume. Two gallons (7.57 liters) <br />Dimensions (hetghtxwidthxdepth): <br />13x ll x ll inches (33.02x27.94x27.94 cm) <br />Material. Polyethylene plastic <br />Switch: <br />Type: Single pole, single throw <br />Rating- 10 VA, 110 to 240 VAC <br />Stem and float material: Polysulfone <br />Operating Temperature. 0 to 225 °F <br />(-18 to 107°C) <br />Pressure: 50 psi maximum <br />Leadsm 2t2 AWG <br />Approved: • <br />Vii' �1, r ' • <br />'IT <br />The Ronan Model X76S Leak Detector Monitor System <br />can be configured to meet the different local and state <br />codes for underground storage by proper selection of <br />sensors and monitor modules. For example, a particular <br />local code and/or type of facility may require leak detection <br />of a tank annulus. The monitor system would consist of the <br />following items: <br />Model X76S-( ) <br />1— No. of alarm inputs (1 thru 4) max -4 <br />Accessories <br />Qty Type <br />LS -3 (Vertical liquid level sensing probe) <br />LS -7 (Horizontal liquid level sensing probe) <br />LS -10 (Reservoir liquid level system) <br />HV Vapor Sensor (Specify product <br />being monitored) <br />Tank Leak Sensor, Model LS -3 <br />Housing:304 stainless steel <br />vlrarranty: Ronan warrants equipment of its own manufacture to be <br />free from defects in material and workmanship under normal conditions <br />Switch: <br />of use and service, and will repair or replace any component found to be <br />Type: Single pole, single throw N.C. <br />defective, on its return, transportation charges prepaid, within one year <br />10 VA, 110 to 240 VAC <br />Rating:expressed <br />of its original purchase. This warranty carries no liability, either <br />or implied, beyond our obligation to replace the unit which <br />Stem and float material: Fuel -proof polysulfone carries the warranty. <br />RONAN ENGINEERING <br />ROWAN COMPANY <br />RONAN ENGINEERING RONAN ENGINEERING RONAN ENGINEERING <br />LTD. U.K. LIMITED (RUST.) PTY. LTD. <br />P.O. Box 1275 <br />1 Tilley Road 32 Bermondsey Road Unit 10, 8 Leighton Place <br />21200 Oxnard Street <br />Crowther District 3 Toronto, Ontario Hornsby, N.S.W. 2077 <br />Woodland Hills, <br />Washington. Tyne and Wear Canada M4BIZ5 Australia <br />California 91367 U.S.A. <br />United Kingdom, NE38-OEA (416) 752-0310 • Telex 63662 (02) 477-7344 a Telex 73467 <br />(818) 883-5211 • Telex 698-490 <br />(091) 416-1689 0 Telex 537-746 FAX (416) 752-8072 FAX (02) 477-6151 <br />FAX (818) 992-6435 <br />FAX (091) 416-5856 <br />6/1286 Printed in U.S.A <br />X7 <br />