Laserfiche WebLink
TEST DATE: 04/09/97 <br />CLIENT: SHELL PRODUCTS <br />TANKNOLOGY-NDE <br />WORK ORDER NUMBER: 2201013 <br />SITE: SHELL 204-7524-3505 <br />Tank ID: i <br />Material: DW FIBERG <br />Bottom to top fill in inches: <br />171.0 <br />Product: PREMIUM <br />Tank manifolded: NO <br />Bottom to grade fill in inches: <br />180.0 <br />Capacity in gallons: 14,976 <br />Vent manifolded: No <br />Fill pipe length in inches: <br />53.0 <br />Diameter in inches: 120.00 <br />Vapor recovery manifolded: YES <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 277 <br />Impact Valves Operational: Y <br />Stage I vapor recovery: <br />DUAL <br />Tank age (years): <br />Overfill protection: <br />Stage II vapor recovery: <br />ASSIST <br />Fuel pure rating: <br />Overspill protection: <br />Installed: <br />COMMENTS <br />3.4:00 <br />Flow rate (cfh): <br />Finish psi: <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />UFT/OFT: <br />Make: RED JACKET <br />Fluid volume in gallons: <br />Model: X.L.P. <br />Tank water level in inches: <br />S/N: 23.0939802 <br />Test time: <br />Open time in sec: 3.00 <br />Number of thermisters: <br />Holding psi: 10 <br />Specific gravity: <br />Resiliancy cc: 300 <br />Water table depth in inches: <br />Test leak rate mVm: 189.0 <br />Determined by (method): <br />Metering psi: 10 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />Test time: <br />Material: <br />DW FIBERG <br />Ullage volume: <br />Diameter (in): <br />2.0 <br />Ullage pressure: <br />Length (ft): <br />120.0 <br />Results: <br />Test psi: <br />5o <br />Bleedback cc: <br />115 <br />Test time (min): <br />30 <br />DATA FOR UTS-4T ONLY: <br />Test 1: Start time: <br />13:50 <br />Time of test 1: <br />Finish psi: <br />47 <br />Temperature: <br />Vol change cc: <br />3.7 <br />Test 2: Start time: <br />3.4:00 <br />Flow rate (cfh): <br />Finish psi: <br />so <br />Time of test 2: <br />Vol change cc: <br />o <br />Test 3: Start time: <br />14:10 <br />Temperature: <br />Finish psi: <br />so <br />Flow rate (cfh): <br />Vol change cc: <br />o <br />Time of test 3: <br />Final gph: <br />0.009 <br />Temperature: <br />Result: <br />PASS <br />Flow rate (cfh): <br />Pump type: <br />PRESSURE <br />COMMENTS <br />Pump make: <br />FE PETRO <br />COMMENTS <br />Printed 09/09/97 16:09 MSHAW <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 <br />