My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_1995-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:09:10 PM
Creation date
6/3/2020 9:43:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2004
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_1995-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
431
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OFII&OGRAM CONSOLIDATED FO* <br />TANKS <br />(Two pages per tank) <br />Page 6 of 7 <br />TYPE OF ACTION ❑ 1. NEW PERMIT ❑ 4. AMENDED PERMIT ❑ 5. CHANGE OF INFORMATION ❑ 6. TEMPORARY TANK CLOSURE 430. <br />(Check one item only) ❑ 3. RENEWAL PERMIT ❑ 7. PERMANENTLY CLOSED ON SITE <br />(Specify reason) (Specify reason) ® 8. TANK REMOVED <br />BUSINESS NAME (Same as FACILITY NAME or DBA -Doing Business As) 3. <br />1 FACILITY ID: <br />1• <br />LOCATION WITHIN SITE (Optional) 431• <br />Country Club Shell, 2575 Country Club Blvd., Stockton, CA 95204 <br />I. TANK DESCRIPTION <br />(A scaled plot pian with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br />TANK ID # 432• <br />TANK MANUFACTURER 433. <br />COMPARTMENTALIZED TANK [:]Yes No 434. <br />136144 - WO <br />Owens-Cornin <br />If "Yes," complete one page for each compartment. <br />DATE INSTALLED 435. <br />TANK CAPACITY IN GALLONS 436. <br />NUMBER OF COMPARTMENTS 437. <br />(YEAR/MO) <br />1987 <br />550 <br />NA <br />ADDITIONAL DESCRIPTION (For local use only) 438. <br />IL TANK CONTENTS <br />TANK USE 439• <br />PETROLEUM TYPE azo. <br />❑ 1. MOTOR VEHICLE FUEL <br />❑ la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br />(If checked, complete Petroleum Type) <br />❑ lb. PREMIUM UNLEADED ❑ 3. DIESEL ❑ 6. AVIATION GAS <br />❑ 2. NON -FUEL PETROLEUM <br />❑ Ic. MIDGRADE UNLEADED ❑ 4. GASOHOL ® 99. OTHER: Waste Oil <br />❑ 3. CHEMICAL PRODUCT <br />COMMON NAME (from Hazardous Materials Inventory page) 441. <br />CAS# (from Hazardous Materials Inventory page) 442. <br />® 4. HAZARDOUS WASTE <br />NA <br />NA <br />(Includes Used Oil) <br />❑ 95. UNKNOWN <br />III. TANK CONSTRUCTION <br />TYPE OF TANK ❑ 1. SINGLE WALL ❑ 3. SINGLE WALL WITH EXTERIOR ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443• <br />(Check one item only) MEMBRANE LINER ❑ 95. UNKNOWN <br />® 2. DOUBLE WALL ❑ 4. SINGLE WALL IN A VAULT ❑ 99. OTHER <br />TANK MATERIAL - primary tank ❑ 1. BARE STEEL ® 3. FIBERGLASS / PLASTIC ❑ 5. CONCRETE ❑ 95. UNKNOWN 444. <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 8. FRP COMPATIBLE ❑ 99. OTHER: <br />REINFORCED PLASTICFRP W/100% METHANOL <br />TANK MATERIAL - secondary tank [3I. BARE STEEL ® 3. FIBERGLASS/ PLASTIC ❑ 8. FRP COMPTIBLE W/100% METHANOL ❑ 95. UNKNOWN 445. <br />(Check one item only) ❑ 2. STAINLESS STEEL ❑ 4. STEEL CLAD W/FIBERGLASS ❑ 9. FRP NON-CORRODABLE JACKET ❑ 99. OTHER <br />REINFORCED PLASTIC (FRP) ❑ 10. COATED STEEL <br />❑ 5. CONCRETE <br />TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑ 3. EPDXY LINING ❑ 5. GLASS LINING ❑ 95. UNKNOWN 446. <br />DATE INSTALLED 447. <br />OR COATING ❑ 2. ALKYD LINING ❑ 4. PHENOLIC LINING ® 6. UNLINED (:199. OTHER <br />Check one item only) <br />OTHER CORROSION ❑ 1. MANUFACTURED CATHODIC ® 3. FIBERGLASS REINFORCED PLASTIC ❑ 95. UNKNOWN 448. <br />DATE INSTALLED 449. <br />PROTECTION PROTECTION ❑ 4. IMPRESSED CURRENT ❑ 99. OTHER <br />If A licable ❑ 2. SACRIFICIAL ANODE <br />SPILL AND OVERFILL YEAR INSTALLED 450. <br />TYPE 451. <br />OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br />(Check all that apply) ❑ 1. SPILL CONTAINMENT <br />❑ 1. ALARM _ ❑ 3. FILL TUBE SHUT OFF VALVE <br />❑ 2. DROP TUBE <br />❑ 2. BALL FLOAT [14. EXEMPT <br />❑ 3. STRIKER PLATE <br />IV. TANK LEAK DETECTION <br />(A description of the monitoring program shall be submitted to the local agency.) <br />IF SINGLE WALL TANK 453• <br />IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br />(Check all that apply) <br />(Check one item only) <br />❑ 1. VISUAL (EXPOSED PORTION ONLY) ❑ 5. MANUAL TANK GAUGING (MTG) <br />❑ 1. VISUAL (SINGLE WALL IN VAULT ONLY) <br />❑ 2. AUTOMATIC TANK GAUGING (ATG) ❑ 6. VADOSE ZONE <br />❑ 2. CONTINUOUS INTERSTITIAL MONITORING <br />❑ 3. CONTINUOUS ATG ❑ 7. GROUNDWATER <br />❑ 3. MANUAL MONITORING <br />❑ 4. STATISTICAL INVENTORY RECONCILIATION ❑ 8. TANK TESTING <br />(SIR) + BIENNIAL TANK TESTING ❑ 99. OTHER <br />V. TANK CLOSURE INFORMATION / PERMANENT <br />CLOSURE IN PLACE <br />ESTIMATED DATE LAST USED (YR/MO/DAY) 455. <br />ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. <br />TANK FILLED WITH INERT MATERIAL? 457. <br />gallons <br />❑ Yes ❑ No <br />UPCF hwfwrc-b (1/99) -1/4 http://www.unidocs.org Rev. 02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.