Laserfiche WebLink
TEST DATE: J'ine 23, 1995 <br />CLIENT: AMERICAN CONSTRUCTION & <br />WORK ORDER NUMBER: 964384 <br />SITE: SHELL <br />Tank ID: <br />1 <br />Bottom to top fill in inches: <br />171.0 <br />Product: <br />PREMIUM <br />Bottom to grade fill in inches: <br />180.0 <br />Capacity in gallons: <br />15,000 <br />Fill pipe length in inches: <br />53.0 <br />Diameter in inches: <br />118.00 <br />Fill pipe diameter in inches: <br />4.0 <br />Length in inches: <br />320 <br />Stage I vapor recovery: <br />DUAL <br />Material: <br />DW FIBERG <br />Stage II vapor recovery: <br />ASSIST <br />Tank: <br />No <br />Resiliency cc: <br />Water table depth in inches: <br />Manifolded Vent: <br />No <br />Determined by (method): <br />NO WELL <br />Test method: <br />VPLT <br />New/passed Failed/replaced <br />Psi at tank bottom: <br />1.80 <br />detector detector <br />Fluid level in inches: <br />68.00 <br />Test method: FTA <br />UFT/OFT: <br />UFT <br />Make: <br />Fluid volume in gallons: <br />8,951 <br />Model: <br />Water level in inches: <br />0.00 <br />S/N: <br />Test time: <br />16:59-19:16 <br />Open time in sec: <br />Number of thermisters: <br />10 <br />Holding psi: <br />Specific gravity: <br />0.722 <br />Resiliency cc: <br />Water table depth in inches: <br />e <br />Test leak rate ml/min: <br />Determined by (method): <br />NO WELL <br />Metering psi: <br />Leak rate in gph: <br />-0.014 <br />Calib. leak in gph: <br />RESULT: <br />PASS <br />RESULT: <br />.. C�MEfyfTS 1IMIf*N.. <br />Test method: UTS-4T system <br />Test time: 20:15-21:40 <br />Ullage volume: 6,049 <br />Ullage pressure: 2.20 <br />RESULT: PASS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: 21:08-21:18 <br />Temperature: 71.80 <br />Flow rate (cfh): 0.200 - <br />Time of test 2: 21:19-21:29 <br />Temperature: 71.90 <br />Flow rate (cfh): 0.200 - <br />Time of test 3: 21:30-21:40 <br />Temperature: 71.90 <br />Flow rate (cfh): 0.200- <br />COMIUIt~NT .... <br />Material: DW FIBERG <br />Diameter (in): <br />2.0 <br />Length (ft): <br />70.0 <br />Test psi: <br />50 <br />Bleedback cc: <br />85 <br />Test time (min): <br />30 <br />Test 1: start time: <br />20:30 <br />finish psi: <br />50 <br />vol change cc: <br />0 <br />Test 2: start time: <br />20:40 <br />finish psi: <br />47 <br />vol change cc: <br />14 <br />Test 3: start time: <br />20:50 <br />finish psi: <br />49 <br />vol change cc: <br />e <br />Final gph: <br />0.012 <br />RESULT: <br />PASS <br />Test type: PTK-88 <br />Pump type: e: PRESSURE Pump make: <br />TEXAS 78754 (512) 719-4633 <br />FE PETRO <br />