My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2575
>
2300 - Underground Storage Tank Program
>
PR0231070
>
COMPLIANCE INFO_1995-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2023 2:09:10 PM
Creation date
6/3/2020 9:43:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2004
RECORD_ID
PR0231070
PE
2351
FACILITY_ID
FA0006439
FACILITY_NAME
COUNTRY CLUB MOBIL CIRCLE K
STREET_NUMBER
2575
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
2575 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231070_2575 COUNTRY CLUB_1995-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
431
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UST SYSTEM PRINTSET INFORMATION <br />1. <br />## <br />Four complete sets of plans (To include specification sheets and/or equipment brochures if not on file). <br /># <br /># <br /># <br />2. <br />/\ <br />Plans drawn to scale in non -erasable print. <br />_ (1) <br />Striker plate dimensions and materials. <br />3. <br />(2) <br />Plot plan to show location and number of tanks. <br />(3) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />4. <br />2 <br />Tank cross-sectional diagram included on prints submitted. <br />(1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />5. <br />1Detail <br />of tank, piping system, excavation and cover. <br />(2) <br />Approved by a corrosion engineer or N.A.C.E. technician. <br />6. <br />X <br />Tank(s) and piping approved by a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br />Article 3, Sec. 2631 (r) & 26351 <br />CORROSION PROTECTION <br />7. <br />Verification of product compatibility with the tank(s), piping, monitoring <br />U.L. LISTED <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)3 <br />COMPATIBILITY WITH 100% <br />IL METHANOL <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. [Section 2635 (b) (5)] <br />9. <br />Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />[Section 2635 (b) (6) & (7)] <br />10. <br />Double walled tanks using pressure or vacuum testing to monitor the annular space. [Section 2635 (b) (7)] <br />11. <br />Z <br />NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />be submitted directly to PHS/M from the testing company or owner of facility. [Health & Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (5)] <br />17_ <br />TANC COMPOSITION <br />TANK # <br />## <br />,,ttTANK(s) <br />4L A. <br /># <br /># <br /># <br />CAPACITY <br />7 <br />15K, <br />_ (1) <br />Striker plate dimensions and materials. <br />MANUFACTURER <br />(2) <br />Striker plate under all accessible openings. <br />(3) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />COMPOSITION <br />Non -clad steel tank [Section 2635 (b)] <br />(1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />MODEL <br />etc.). <br />1 <br />0 Dift.- <br />(2) <br />Approved by a corrosion engineer or N.A.C.E. technician. <br />PRODUCT <br />Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />b` 6 <br />CORROSION PROTECTION <br />U.L. LISTED <br />COMPATIBILITY WITH 100% <br />IL METHANOL <br />13. TO BE INSTALLED <br />,,ttTANK(s) <br />4L A. <br />Steel -clad with fiberglass reinforced plastic. <br />B. <br />Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). [Section 2635 (b) (4)] <br />C. <br />Fiberglass <br />[Sections 2635 (3) and 2631 (p)] <br />_ (1) <br />Striker plate dimensions and materials. <br />(2) <br />Striker plate under all accessible openings. <br />(3) <br />Installation instructions require an air test and soap bubble test prior to installation. <br />N D. <br />Non -clad steel tank [Section 2635 (b)] <br />(1) <br />Cathodic protection provided for entire tank, piping and components (nuts, bolts, washers, <br />etc.). <br />(2) <br />Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) <br />Document stating inspection method and frequency (minimum semi-annual inspection requirement). <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.