Laserfiche WebLink
j -•- <br /> NIFIED PROGRAM CONSOLIDATED FORM <br /> �ANKS <br /> UNDERGROUND STORAGE TANKS'- TANK PAGE 2 ,° <br /> „,,VI.PIPING.CONSTRUCTION(Chwkellthatappty} " <br /> -DERGROUND PIPING VQ . /)IJCA4I8�RO;l 11lG,�E1 II,� J r� ABOVEGROUND PIPING <br /> iYSTEM TYPE F 1. PRESSURE I' 2. SUCTION r 3. GRAVITY r 1. PRESSURE r 2. SUCTION r 3. GRAVITY 459 <br /> ;ONSTRUCTION F 1. SINGLE WALL F 3. LINED TRENCH I 99. OTHER F 1. SINGLE WALL F95. UNKNOWN 462 <br /> F 2. DOUBLE WALL r 95. UNKNOWN r 2. DOUBLE WALL r 99. OTHER <br /> AANUFACTURE MANUFACTURER 461 MANUFACTURER 463 <br /> 2 <br /> r 1.BARE STEEL I 6. FRP COMPATIBLE W/100%METHANOL I 1. BARE STEEL I 6. FRP COMPATIBLE W/100%METHANOL <br /> AATERIALS AND r 2. STAINLESS STEEL r 7. GALVANIZED STEEL r 2. STAINLESS STEEL r 7. GALVANIZED STEEL <br /> IROTEON <br /> C IO I 3. PLASTIC COMPATIBLE WITH CONTENTS I'95. UNKNOWN r 3. PLASTIC COMPATIBLE WITH CONTENTS r 8. FLEXIBLE(HDPE) r 99. OTHER <br /> 'ROTECTION <br /> r 4. FIBERGLASS r 8. FLEXIBLE(HDPE) r 99. OTHER r 4. FIBERGLASS I'9. CATHODIC PROTECTION <br /> I 5. STEEL W/COATING IF 9. CATHODIC PROTECTION 464 r 5. STEEL W/COATING r95. UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check alt that apply)(A description of the monitoring ptgprem 8h4ll be,submltted tP the local agency) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> TINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> 'RESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check ell that apply): <br /> 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR r 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS F 2. MONTHLY 0.2 GPH TEST <br /> 2. MONTHLY 0.2 GPH TEST <br /> F 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 3. ANNUAL INTEGRITY TEST(0.1-GPR" <br /> 4. DAILY VISUAL CHECK <br /> :ONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> 5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY I 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) I 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> iAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> 7. SELF MONITORING r 7. SELF MONITORING <br /> WITY FLOW: GRAVITY FLOW(Check all that apply): <br /> BIENNIAL INTEGRITY TEST(0.1 GPH) r 8. DAILY VISUAL MONITORING <br /> I 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> iECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> 'RESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10 US TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND Check one) 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS r a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> r b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM I b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> DISCONNECTION <br /> r c. NO AUTO PUMP SHUT OFF r c. NO AUTO PUMP SHUT OFF <br /> 11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR r 11. AUTOMATIC LEAK DETECTOR' <br /> RESTRICTION <br /> 12. ANNUAL INTEGRITY TEST(0.1 GPH) I 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ;UCTION/GRAVITY SYSTEM: SUCTIONIGRAVITY SYSTEM: <br /> 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS I 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check ell that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND I 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> VISUAL ALARMS ALARMS <br /> 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR I 15, AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> RESTRICTION <br /> 16. ANNUAL INTEGRITY TEST(0.1 GPH) I 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 17. DAILY VISUAL CHECK I1 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER.C.ONTAINMENT <br /> ASPENSER CONTAINMENT h 1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE 14. DAILY VISUAL CHECK <br /> DATE INSTALLED 468 r 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS r 5. TRENCH LINER/MONITORING <br /> r 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS r 6. NONE 469 <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> c GNAT E OF O ER/OPERATOR DATE 470 <br /> 4/5/02 <br /> wat F OWNER/OPERATOR(pant) 471 TITLE OF OWNER/OPERATOR 472 <br /> Bruce T. Marubashi for Shell Oil Products US H,S&E Analyst(925)766-3498 <br /> Permit Number(For local use only) 473 I Permit Approved(For local use only) 474 I Permit Expiration Date(For local use only) 475 <br /> IPCF(1/99 revised) 7 Formerly SWRCB Form B <br />