My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2007-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 10:36:46 AM
Creation date
6/3/2020 9:43:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2008
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2007-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Water Boards: LG 113 Page 1 of 2 <br />Issue Date: November 22, 1995 <br />Revision Date: May 20, 2003 <br />TLS -300 Series, TLS -350 Series, EMC Series, EMC Basic, Red Jacket ProMax and ProPlus wi <br />Single Stage Hydrostatic Sensor 794380-301, <br />Dual Stage Hydrostatic Sensors 794380-302, 303 <br />014 11441 to]' • • <br />Output type: qualitative <br />Sampling frequency: continuous <br />Operating principle: float switch <br />Test Results: <br />Single Stage Hydrostatic 30% by weight <br />Sensor 794380-301 calcium chloride in water <br />Product Activation Height (in) 1.74 <br />Response time (min) <br /><1 <br />Recovery time (min) <br /><1 <br />Dual Stage Hydrostatic Sensor <br />water <br />794380-302 <br />high*** <br />low*** <br />Product activation height (in) <br />12.25 <br />1.62 <br />Response time (min) <br /><1 <br /><1 <br />Recovery time (min) <br /><1 <br /><1 <br />Dual Stage Hydrostatic Sensor <br />30% by weight <br />794380-303 <br />calcium chloride <br />in water <br />high*** <br />low*** <br />Product activation height (in) <br />13.13 <br />1.20 <br />Response time (min) <br /><1 <br /><1 <br />Recovery time (min) <br /><1 <br /><1 <br />**50% by weight <br />ethvlene alvcol in water <br />1.5 <br />35.75 <br /><1 <br />**Evaluation performed by Carnegie Mellon Institute. <br />***The "high" and "low" refer to high and low level alarm points of dual stage hydrostatic sensors. <br />Comments: <br />EMC Series and EMC Basic controllers have been evaluated only for use with sensors 794380-301 and 794380-30 <br />Evaluator reports that sensors will respond to any liquid after their thresholds are exceeded. <br />Response times measured from trigger point, except for sensor 794380-301 with 50% by weight ethylene glycol <br />http://www.swrcb.ca.gov/ust/leak_prevention/lgl13Nendor Files/veeder root_q.html 1/7/2008 <br />
The URL can be used to link to this page
Your browser does not support the video tag.