My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2007-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 10:36:46 AM
Creation date
6/3/2020 9:43:39 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2008
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2007-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
n <br />Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. <br />A separate permit application is required to install ELD. <br />❑ Complete to scale As -Built Plans <br />❑ Complete Monitoring and Response Plan <br />❑ UPCF Underground Storage Tanks - Installation Certificate of Compliance (one form <br />per tank) <br />❑ Completed Underground Storage Tank Certification of Financial Responsibility form <br />along with any required attachments <br />❑ Passing Line Leak Detector Test Results <br />❑ Passing Line Tightness Test Results (Required if the UST system does not satisfy the <br />California Code of Regulations 2636(8) for automatic pump shut-off.) <br />❑ Passing Enhanced Leak Detection Results <br />D. INSPECTIONS: <br />Note: A representative from the San Joaquin County Environmental Health Department <br />must witness all activities described below. <br />® ❑ Tank holiday test (for fiberglass -coated steel tanks) performed prior to installation in <br />excavation <br />❑ Inspection of tank vacuum gauge (if applicable) prior to placement in excavation <br />❑ Tank soap test (for fiberglass tanks) performed prior to installation in excavation <br />❑ Verification of tank set and anchorage in excavation <br />❑ Primary piping including product piping, vapor recovery and vent line piping soap and <br />pressure test <br />❑ Secondary piping including product piping, vapor recovery and vent line piping soap <br />and pressure test <br />❑ 24 -Hour secondary containment lake test on sumps and under -dispenser containment <br />❑ Visual inspection of piping to ensure proper slope prior to covering <br />❑ Overfill performance test <br />❑ Prior to receiving fuel, a complete functional test of tank and piping monitoring <br />system(s) including overfill prevention <br />❑ Final inspection and demonstration of automatic shut down (if applicable). <br />Revised 8/3/07 5 <br />