My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FAIRMONT
>
975
>
2300 - Underground Storage Tank Program
>
PR0231331
>
COMPLIANCE INFO_2015-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2023 2:14:17 PM
Creation date
6/3/2020 9:44:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015-2018
RECORD_ID
PR0231331
PE
2351
FACILITY_ID
FA0000513
FACILITY_NAME
LODI MEMORIAL HOSPITAL
STREET_NUMBER
975
Direction
S
STREET_NAME
FAIRMONT
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
03107039
CURRENT_STATUS
01
SITE_LOCATION
975 S FAIRMONT AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231331_975 S FAIRMONT_2015-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Aris Veloso [EH] <br /> From: Aris Veloso [EH] <br /> Sent: Tuesday,January 27, 2015 9:36 AM <br /> To: 'gmoses@lodihealth.org' <br /> Subject: Lodi Memorial Hospital CERS corrections needed <br /> UST refected via CERS <br /> This UST submittal was rejected by Aris Veloso, RENS, ICC Certified UST Inspector, on 1-27-15. The <br /> following items need to be addressed/corrected: <br /> Tank# TA0515887 (20,000 gallon diesel)UST Monitoring Plan: <br /> Tank Description Tank ID# should be TA0515887 not tao515887. <br /> Continuous Monitoring of Piping Secondary Containment should be marked yes. Marking yes should open up <br /> more applicable sections which may require additional information. <br /> Periodic System Testing Secondary Containment testing should be marked no. <br /> Tank# TA0133103 (5,000 gallon diesel)UST Tank Information/Monitoring Plan: <br /> Tank Description Tank ID# should be TA0133103 not tao133103. <br /> Tank Construction Primary Containment should be steel, Secondary Containment should be jacketed. <br /> Vent, Vapor Recovery(VR) and Riser/Fill Pipe Piping Construction Primary Containment should be steel. Riser <br /> Pipe Primary Containment should be steel. <br /> Tank# TA0133103 (5,000 gallon diesel) Monitoring Plan: <br /> Pipe Monitoring is Performed Using the Following Method(s) Pipeline Integrity Testing should be marked yes. <br /> UST Monitoring Site Plan Supplemental Documentation UST Monitoring Site Plans must include a Site Plan <br /> showing the general tank and piping layouts and the locations where monitoring is performed (i.e., location of <br /> each sensor, line leak detector, monitoring system control panel, etc.). Upload needed for each UST. <br /> UST Certification of Financial Responsibility Documentation needs to be updated and re-uploaded. The <br /> insurance listed indicated an end date of 10-31-14. <br /> UST Letter from Chief Financial Officer Supplemental Documentation should list 10,000 per occurrence and <br /> 10,000 annual aggregate coverage. This letter is in support of the use of the UST Cleanup Fund. Therefore, the <br /> Certification of Financial Responsibility should also list the UST Cleanup Fund mechanism. If you prefer <br /> insurance as your only mechanism, then the UST Cleanup Fund does not need to be listed on the Certification <br /> of Financial Responsibility nor does the Letter of Chief Financial Officer need to be completed. <br /> Please contact me at aveloso(z:;sjcelid.com or(209) 468-3453 if you have any questions. <br /> Aris Veloso, REHS <br /> San Joaquin County Environmental Health Department <br /> 1868 E. Hazelton Ave. <br /> Stockton, CA 95205 <br /> desk 209 468-3453 <br /> fax 209 468-3433 <br /> email aveloso sicehd.com <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.