My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 11:56:42 AM
Creation date
6/3/2020 9:44:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
435
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> f I . <br /> 3. Pi in Leak Detection MonitorlAtquipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> Sump leak sensors connected to Veeder Root 794380-208 <br /> continuous monitoring system <br /> Specify type: Continuous <br /> Discriminating <br /> ®Non-discriminating <br /> Mechanical line leak detectors with Vapodess LD-2000 <br /> programmed leak threshold of three Every pumping cycle <br /> gallons per hour <br /> Electronic line leak detectors with <br /> programmed leak threshold of: Every pumping cycle <br /> 0.1 aph 0.2 aph 3 gPh <br /> Line integrity testing by: <br /> ❑Electronic line leak detector is <br /> equipped to conduct line tightness ❑Annually <br /> testing ❑ Other: <br /> ❑Third party testing <br /> ®Not required <br /> ❑Other(Specify): <br /> 4. Dispenser Leak Detection Monito ng Equipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> Mechanical float in dispenser Continuous <br /> containment <br /> Electronic leak sensor in dispenser Veeder Root 794380-208 <br /> containment: <br /> F1 Discriminating <br /> Continuous <br /> ®Non-discriminating <br /> ❑Visual inspection Visual inspection log maintained on site. Ll Daily <br /> ❑Other: <br /> No under-dispenser containment <br /> ❑Other(specify):Mechanical Float activates shear valve when leak detected. <br /> 6. Positive Shutdown Capabilities <br /> 9 System does not have positive shutdown capabilities <br /> Ll Individual dis nser shutdown will occur whenever release is sensed in under-dis nser containment <br /> Automatic pump shut off will occur whenever. <br /> ®Release is sensed in turbine sump <br /> ❑Release is sensed in primary piping <br /> ®Release is sensed at dispenser <br /> ®Monitoring system is disconnected or fails in any way(fail safe) <br /> ❑Other(specify): <br /> 6.Secondary Containment Testing <br /> Seconda containment is not tested <br /> In the State of California,secondary containment systems installed on or after January 1,2001,shall be tested upon installation, <br /> six months after installation,and every 36 months thereafter. Secondary containment systems installed prior to January 1,2001, <br /> shall be tested by January 1,2003,and eve 36 months thereafter. <br /> 7. Annual E ui ment Certification/Testing <br /> Annuals <br /> ❑Other(specify): <br /> 2 <br />