My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2006-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 1:10:36 PM
Creation date
6/3/2020 9:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2007
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2006-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I <br /> t <br /> i <br /> i <br /> Page 15 of <br /> i <br /> _ I UNDER DISPENSER CONTAIN1VlENT <br /> (UDC)TESTING <br /> Test Method Developed By: UDC Manufacturer [❑ Industry Standard ® Professional Engineer p i <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum Q Hydrostatic ® j <br /> Other(Specify) f <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution:.00007 <br /> Under-Dispenser,Containment Number Below <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: �? '-"' --- �—••- ---~ - <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to -- j <br /> testing*. �fC 2�fc a7 i <br /> Portion of UDC Iestedt 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ; <br /> UDC sensor detects liquid. D Yes❑ No NAM ❑Yes❑ No NAM Q Yes❑ No NA® El Yes❑ No NA® j <br /> - t <br /> Turbine shutdown response time ❑Yes Q No NAM ❑Yes❑ No NA® ❑Yes Q No NAM p Yes Q Na NA® { <br /> Is system programmed for fait- <br /> safe shutdown?� ®Y�© No NA® El ❑ No NA® ❑Yes❑ No NAM ❑Yes❑ No NAM j <br /> Was fail-safe verified to be operational?" ❑Yes❑ No NAM ®Yes Q No NAM ❑Yes❑ No NAM Q Yes❑ No NAM <br /> Wait time between applying <br /> pressure/vacuum/water and l5 Minutes IS Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: .2 Z ;d 2 t 2 Z =c, <br /> Initial Reading{Ri}: z. S" 79 6 ;3 <br /> Test End Time: 2..3 7 _' 2, 2� ' .z:C �.' <br /> Final Reading(RF): 2ZZ z A, 3 �. �► Sz Z Ja. a <br /> I <br /> Test Duration: 15 Min 15 Min. 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(Ry-R,): dr,�� a� <br /> Pass/Fail Threshold or Criteria: <br /> -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -4.0020 -0.0020 -0.0024 � <br /> 'pook�ee <br /> ...... ...........•. .................\:...:.......:•.�..:* a rail`_..:.;. '.`.,+. ,r.:"•.i � - :{� - <br /> .i?ta� �:d;,7?ail�_ ,'' Fail;;>°-`��;�.�:�fll��'1'•��; 3' ,1�•;^y5`k- ;.ti; <br /> Was sensor removed for testing? Yes[( No NACU l NA Yes❑ No :{ zdildt <br /> --r— ❑ Ycs❑ No NA® <br /> � . <br /> Was sensor properly replaced and Yes 171 No:NA[JYes❑ No NAQhYes❑ No NA❑ es❑ No NAQ <br /> verified functional after testing?- Yes❑ No NA❑ <br /> r <br /> Comments—(include in mination on re airs made t Mi to testin ,and recommended ollow-u of failed tests) <br /> i <br /> i <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.