Laserfiche WebLink
4PE T Dispatch cS <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State o�f'California <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> Chis form must be used to document testing and servicing of monitoring equipment. A se irate certification or re ort must be nre ared for each <br /> nonitorinLy system control panel by the technician who performs the work. A copy of this forest must be provide to the tank system owner operator. <br /> e owner/operator must submit a copy of this form to the local agency regulating TJST systems within 30 days of test date. <br /> k.' General Information <br /> acility Name: CO '2133 Bldg.No.: <br /> lite Address: ? r City Uc' 1 "t' dip: �; 7 <br /> ;acility Contact Person:_ `/L Contact Phone No.: ( 14-7-25-- <br /> vlake/Model of Monitoring System:�0�V? Tt z S"O Serial Number f ZS j t 5-C 91 tt p Q 2- <br /> )ate of Testing/Servicing: / / 06 <br /> B. Inventory of Equipment'Tested/Certified 0:1 /,y -i'e s�� 3 Z,3 so m t 5 <br /> heck thea ro riate boxes to indicates e¢ific mai2ment ins eeted/serviced: <br /> rank ID: 'TI u r Tank ID: <br /> In-Tank Gauging Probe. Model: (` <br /> ❑ In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> 3"Piping Sump/Trench Sensor(s). Model: ']2 y 3 g p - 6 � KI-Piping Sump/Trench Sensor(s). Model: 7 q y 3 a S <br /> B'Fill Sump Sensor(s). Model: q y ®- Z R-Fill Sump Sensor(s). Model: ?g y3 A�--,3 z <br /> � Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> 3 Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> D Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> R Other(s2E! equipment type and model in Section E oneP � 2}. ❑ Other(s eci equipment a and model in Section E on Page 2). <br /> rank ID:'l-3 GolddTank ID: <br /> D In-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model: <br /> Z) Annular Space or Vault Sensor. Model: ❑ Annular Space or Vault Sensor. Model: <br /> B"Piping Sump/Trench Sensor(s). Model: '?`j 00,3Z3 12-Piping Sump/Trench Sensor(s). Model: <br /> ZrFill Sump Sensor(s). Model: 79H3 O —A 2 3 [!'Fill Sump Sensor(s). Model: <br /> :1 Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ZI Electronic Line Leak Detector. Model: 13 Electronic Line Leak Detector. Model: <br /> :1 Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> 2.Other( ecify a ui ment jMe and model in Section E on P e 2). ❑ Other(s ecify 22u, ment a and model in Section E on P e 2). <br /> Dispenser ID: y 2 <br /> Dispenser ID: 5 '{ <br /> ZI Dispenser Containment Sensor(s). Model:_.? 9 y3 Aa- Z3 ❑ Dispenser Containment Sensor(s). Model: 7 95',3 &o-S t <br /> 3 Shear Valve(s). ❑ Shear Valve(s). <br /> ZI Dispenser Containment Float(s) and Chain(s). ❑ Dis enser Containment Float(s)and Chain(s). <br /> Dispenser ID: S <br /> Despenser ID: � � <br /> 7 Dispenser Containment Sensor(s). Model: 7 7 8D -3 z Dispenser Containment Sensor(s). Model: _751/3-90-32-3 <br /> Shear Valve(s). ❑ Shear Valve(s). - <br /> p Dis enser Containment Float(s)and Chains. ❑ Di enser Containment Flo! s)and Chains . <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ZI Shear Valve(s). ❑ Shear Valve(s). <br /> DDispenser Containment Floats and Chain(s). ❑ Di enser Containment Floats)and Chains . <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information(e.g. manufacturers' checklists)necessary to verify that this information is correct and a <br /> Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the <br /> report,(check all that apply): 3-System set-up C-Alarm history report <br /> Technician Name(print): /ps f f� <br /> Signature: - <br /> :ertification No.: A 3("j[7 License.No.: 302015 <br /> Cesting Company Name: CHARLES E. THOMAS COMPANY Phone No.: (310 ) 323 6730 <br /> address: 13701 So. Alma, Gardena, GaladOrnia 90249 Date of Testing/Servicing: G //q /06 <br /> Page 1 of 3 <br />