My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2006-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 1:10:36 PM
Creation date
6/3/2020 9:44:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2007
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2006-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING EQUIPMENT LIST <br /> # iDESCRIPTION MANUFACTURER MODEL # PART # <br /> 1 42" DIAMETER MULTI-PORT SPILL CONTAINMENT MANHOLE & FRAME DPW 65218-EVR- 164042RT052 <br /> i <br /> 2 PHASE I BRONZE SWIVEL ADAPTER OPW 61 VSA-EVR 61VSA-1020-EVR <br /> PHASE I VAPOR TOP SEAL CAP OPW 1711T-EVR 1711T-7085 <br /> PHASE I VAPOR RECOVERY SPILL CONTAINMENT. 5 GALLON <br /> P.L3 — 4 OPW 1SC-2100 1SC-2100 VAPOR <br /> CAST IRON, W/DRAIN VALVE PLUG <br /> _ 43 ss <br /> _UFACE SEAL ADAPTER, PHASE I RISER, ATG RISER, & FILL RISER OPW FSA-400 FSA-400 <br /> `\ � J FILL BRONZE SWIVEL ADAPTER OPW 61SALP-EVR 61SALP-1020-EVR <br /> O FILL TOP SEAL CAP OPW 634TT-EVR 634TT-7085 <br /> i <br /> 8 FILL SPILL CONTAINMENT. 5 GALLON CAST IRON, OPW 1SC-2100 1SC-2100 FILL W DRAIN <br /> W/EVR DRAIN VALVE / <br /> 9 JACK SCREW ASSEMBLY IN FILL BUCKET OPW 61JSK-4400-EVR 61JSK-4400-EVR <br /> 70 OVERFILL PREVENTION DROP TUBE VALVE OPW 61 SO-EVR 61SO <br /> 11 FITTING, EXTRACTOR, TEE, 4"X4"X3"X3" OPW 233VM-4433 233VM-4433 <br /> 12 TANK GAUGE PORT COMPONENTS MORRISON BROS. 305XPA 305XPA CAP & RING KIT <br /> 13 THREADED PRESSURE VENT CAP HUSKY 4885 4885 <br /> a. <br /> ' 14 NOT USED <br /> �n 15 WATER SHIELD OPW <br /> X <br /> �" 16 RISER SUPPORT OPW R8-1600 <br /> EXISTING <br /> VENT RISERS <br /> n I FILL CAP + <br /> 0 1 42" MANHOLE <br /> FILL ROTATABLE ADAPTER 3 PHASE I CAP a <br /> EXISTING DRIVE SLAB O <br /> 1 <br /> EXISTING FILL 5 GALLON BUCKET 2 PHASE I ROTATABLE ADAPTER <br /> CANOPY I (W/ DRAIN VALVE) <br /> O4 PHASE 1 5 GALLON BUCKET <br /> 8 VALVE) <br /> Ln <br /> JAOCK SCREW ASSEMBLY 1 ATG CAP AND RING KIT 1 <br /> I FILL SUMP EXISTING TANK — —— — — — —_ — — — — — 0 9 <br /> (TYP') SLA13 EXISTING BUILDING M <br /> EXISTING E.S.O. tJ2 FACE SEAL ADAPTER <br /> INTERSTITIAL MONITOR ® i a WO 5 FACE SEAL ADAPTERO <br /> 5 <br /> I I I II I 5 1 RISER SUPPORT 11 EXTRACTOR FITTING (BEYOND) <br /> I 1 1 0 1 OVERFILL a O <br /> 3 2 1 I O 11 0 I ALARM TLSD350RMOOTONfiOR ® EXISTING P.I.C. UNITS I I [] <br /> ' <br /> SYSTEM <br /> In 3 2 1 I I I I ❑ ro <br /> aI i �I I o nogJ II tI o no II ❑ EXISTING DISPENS <br /> ER ® II z <br /> I ON ISLAND (TYP.) wI0 z <br /> 1 1 <br /> J= <br /> DROP TUBEJ O <br /> W/ FLAPPER <br /> 3 2 1 0 I I m I I m I z SET 0 95% <br /> O I I I I I ❑ I <br /> c_ 10 <br /> I I 1 O I I O <br /> IJ j i <br /> EXISTING TANK I W I I\ I\ ❑ ❑ ❑ ❑ 13 <br /> ' SLAB I I i ♦ i Z <br /> Io al <br /> Io ml <br /> LLI m 4 : <br /> _. <br /> L <br /> EXISTING UNDERGROUND � � DEFLECTION PLATE <br /> TANKS as <br /> < <br /> I STAGE I VAPOR RECOVERY & FILL DETAIL IGASOLINEI <br /> TURBINE SUMP I N.T.S. <br /> (TYP.) <br /> i <br /> SCOPE OF WORK <br /> THE SCOPE OF WORK, IN GENERAL, IS THE REPAIR, REPLACEMENT AND ADJUSTMENT OF COMPONENTS OF THE EXISTING ENHANCED <br /> VAPOR RECOVERY SYSTEM INCLUDING THE FOLLOWING: <br /> O REPLACE 4" STEEL RISERS/NIPPLES AS NEEDED TO ADJUST FOR PROPER HEIGHT. <br /> PLANTER <br /> i <br /> PLANTER O INSTALL FACE SEAL ADAPTER - OPW #FSA-400. <br /> —_ — PL=165.88' R=1,120' <br /> PLANTER O PROVIDE TESTING AND INSPECTIONS AS REQUIRED. <br /> ` EXISTING APPROACH <br /> PLYMOUTH DRIVE <br /> 10' 0 10' 20' 30' <br /> GRAPHIC SCALE: 1/16"=1'-0" <br /> i <br /> SITE PLAN <br /> i <br /> I <br /> REVISIONS DRAWING RELEASE APPROVAL <br /> NO. DATE DESCRIPTION NO. DATE DESCRIPTION EVR ASSURANCE SCALE: AS NOTED SHEET <br /> TLM PETRO LABOR FORCE, INC. DRAWN BY: <br /> SITE: DATE: 01-04-06 <br /> 9165 BAYSINGER ST. OFFICE: 310-639-2227 ARCO 2133 <br /> DOWNEY, CA 90241FAX: 310-639-2229 2908 BENJAMIN HOLT DR Joe No. TIM-36 of <br /> STOCKTON, CA DRAWING: 2133-EVR <br /> CHECKED BY: <br /> I <br />