Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue,StDddon,California 95205-6232 <br /> T ne:(209)468-3420 Fax:(209) 3433 :www.siaov.om/ehd <br /> UNDERGROUND STORAGE TANK(UST)PROGRAM INSPECTION REPORT CONTINUED <br /> F8`I ARCO Station#2133 FF&I 2908 W. Ben Holt, Stockton Jan 23, 2013 <br /> Name: <br /> VIOLATIONS <br /> HSC=CA Heaffin aid Code'CFR=Code of Federal R Wavons <br /> 1i C1C2 M Cotte Section C1=Ckns 1 'C2=Ctrs 2 vidatiar M=Minor vW111I <br /> 1N11`iMl ' <br /> 702 CCR 2643(e) Bierrm tig Oast of�a rest performed(P�January 1,1'984) IM') <br /> 703 JGGR 2643(d} Trierrrisi line test forWnwdiolm,suction*ft not pwwmed(pre-January 1,1984) lM r) <br /> S99 OlTror: <br /> see attacied ation-oliicw 1, Report"for vioiation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I CLASS 8 or R-NotiCe to Corn <br /> This is a Routine and Monitoring System Certification inspection. The following are Minor-Notice to <br /> Comply violations: #104, 310, 311 <br /> 104. Financial responsibility documents have not been submitted to the EHD. The last financial <br /> responsibility document submitted to EHD was for coverage period between January 1, 2012 through <br /> January 1, 2013. Current financial responsibility documents are required to be submitted annually. A <br /> copy of the current financial responsibility documents were provided to EHD during this inspection. <br /> Violation was corrected. <br /> 310. About 1-2 gallons of liquid in the premium-octane STP sump and about 1/4 gallon of liquid in the <br /> 87-octane slave STP sump were observed. If water could enter into the secondary containment by <br /> precipitation or infiltration, it must be removed and disposed of properly. Immediately remove this liquid, <br /> make a hazardous waste determination per Title 22 hazardous waste regulations, and manage it <br /> accordingly. Observed technician removed and placed the liquid in the hazardous waste container on <br /> site. Violation was corrected. <br /> 311. The 87-octane line leak detector failed to detect a leak when tested. All line leak detectors shall be <br /> capable of detecting a 3-gallon per hour leak at 10 psi. The service technician adjusted the leak <br /> detector, retested it, and it passed. Violation was corrected. <br /> r. <br /> ALL EHD STAFF TWIE ASSOCATED wm+FMJNG ro COMPLY BY THE MM NOTED GATES MILL BE BUM AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHIYS CURRENT HOURLY RATE. <br /> Mr Recaved sr Tlw: <br /> EFS 2302 04119112 Page 3 61 UST INSPECTION(PORT <br />