My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
bp <br /> LINE LEAK DETECTOR TEST <br /> Facility#: 2133 Date: 01/23/13 <br /> Address: 2908 Benjamin Holt Dr. <br /> City, State:Stockton, CA <br /> Testing Information <br /> Product: 87 91 <br /> Manufacturer Veeder-Root VMI <br /> Leak Detector Serial Number 235252 8071018 <br /> Leak Detector Model No. 848480 848480 <br /> Full Operating Pressure(psi): 28 30 <br /> Test Leak Rate(ml/min)(gph) 3.00 3.00 <br /> Bleed Back Rate(ml): 90 90 <br /> Turbine Holding Pressure(psi): 0 18 <br /> Metering Pressure(psi): N/A 22 <br /> Open/Trip Time(mechanical only): N/A 4 <br /> Pass/Fail Pass Pass <br /> Comments: <br /> Note: Pass=Leak detector reads leak and meters line. <br /> Fail=Leak detector did not read leak. <br /> This letter certifies that the annual leak detector tests were performed at the above referenced facility according to the equipment <br /> manufacturers procedures and limitations and the results as listed are to my knowledge true and correct.The mechanical leak test <br /> detector test pass/fail is determined using a low flow threshold trip rate of 3 gph at 10 PSI. <br /> nspected By: Contractor FASTECH-Fueling&Services Technologies, Inc. <br /> Technician: Chad White Alltech Petro Inc. Lic#: 623541 A-Haz <br /> Signature: A402��- <br />