COMPLIANCE INFO_2011-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
2300 - Underground Storage Tank Program
>
PR0231021
>
COMPLIANCE INFO_2011-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 2:32:40 PM
Creation date
6/3/2020 9:44:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2015
RECORD_ID
PR0231021
PE
2361
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
01
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231021_2908 W BENJAMIN HOLT_2011-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
394
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430 <br /> ❑ 1.NEW PERMIT El3.RENEWAL PERMIT ® 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 431a DATE EXISTING UST DISCOVERED: 4306 <br /> I FACILT>CY'INS OR7VIATIUN, . . <br /> FACILITY ID#(Agency Use Only) <br /> {y .( <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) <br /> ARCO 02133 <br /> BUSINESS SITE ADDRESS 103 CITY 104 <br /> 2908 BENJAMIN HOLT DR STOCKTON <br /> II TANS IESCRPTION. .. , <br /> TANK ID# 1 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> Modem Welding ®1.A STAND-ALONE TANK <br /> ,/4 (_..�e • -- .,( ❑2.ONE IN A COMPARTMENTED UNIT. <br /> ' Com leis one page for each compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 1999/04 12,000 1 <br /> VSE'AND CONTENT <br /> TANK USE N EHI <br /> la.MOTOR V .. <br /> IIL,TANKS . .. <br /> CLE FUELING ❑ 16.MARINA FUELING ❑ lc.AVIAT[ONFUELTNG 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ® la.REGULAR UNLEADED ❑ 1c.MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9-OTHER PETROLEUM (specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 4406 <br /> .. : <br /> TYPE OF TANK ❑ 1.SINGLE WALL N 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ® L STEEL ❑ 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL_INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ❑3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN N 99.OTHER(Specify): Steel Clad w/Fiberglass coating 4458 <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS N 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PROIIUCTi/WASTE'PYPTG CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED N 2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(a)(3)) 459 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ I0.RIGIDPLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGIDPLASTIC 4646 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> 'VI VENT, APO t It COVER'S(VR)AND;RI$ER Y SILL PIPE p:11'I$G;CONS'�RUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS i 1 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 64 <br /> 4 <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10,RIGID PLASTIC N 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464n <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL N 4.FIBERGLASS L3 10,RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464 I <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGIDPLASTIC 90.NONE ❑ 99.OTHER(Specify) 4646 <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE N 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 4641, <br /> RISER PRIMARY CONTAINMENT N 1.STEEL ❑ 4.FIBERGLASS 10.RIGID PLASTIC 0 90.NONE El 99.OTHER(Specify) 4641 <br /> 464'I <br /> RISER SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC N 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATE/BOTTOM PROTECTOR N 4.CONTAINMENT SUMP 45la-e <br /> VII UNDER DISPENSER COITAINIVIENT.iTJDC); <br /> CONSTRUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> : <br /> VIII' CORROSION;PROTFCTION <br /> STEEL COMPONENT PROTECTION [12.SACRIFICIAL ANODE(S) [14.IMPRESSED CURRENT N 6.ISOLATION 448• <br /> IX APPLICANT.SIGNATY7RE„ <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> and in full compliance with legal requirements. -- <br /> APPLICANT SIGNATURFJI - DATE r.;r_-,-' 470. <br /> *a-b - �c_j <br /> APPLICANT NAME(print�Jf N N I RIM. MARINAS 471' APPLICANTTITLE Environmental Compliance Spe 472. <br /> y <br /> UPCF UST-A Rev.(12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.