Laserfiche WebLink
San Joaquin County ' <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj oq v.or /q ehd <br />Facility Name: Facility Address: <br />COUNTRY CLUB FOOD & FUEL MINI MART' 1 1856 W COUNTRY CLUB BLVD, STOCKTON <br />Item # I Remarks <br />Date: <br />June 12. 2015 <br />CCR 2712(i) Current monitoring plan approved by the EHD not found on site. <br />An approved copy of the monitoring plans were not available for inspection. A copy of these plans shall be accessible <br />on site at all times. Immediately locate and retain a copy on site. <br />This is a repeat violation, Class II. <br />207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to visually inspect the UST system for leaks, water, or debris within the last 28 months. <br />During the monthly inspection, the designated operator shall visually inspect all spill containers and UDC sumps, and <br />any tank top sump that had an alarm for which there is no record of a service visit. Ensure that designated operators <br />performing monthly inspections at this facility are inspecting all of the required areas and noting it on the on the <br />reports. <br />This is a repeat violation, Class II. <br />208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months. <br />The June 2014 through May 2015 designated operator monthly inspection reports were not found on site. Designated <br />operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and ensure that <br />copies of the previous twelve months of designated operator monthly inspection reports are maintained on site. <br />Submit copies to the EHD. <br />This is a repeat violation, Class II. <br />209 CCR 2715(f) Designated operator employee training not performed or log not kept. <br />The designated operator employee training was not performed or current. The designated operator shall train facility <br />employees for which he or she is responsible in the proper operation and maintenance of the UST system once every <br />12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />This is a repeat violation, Class II. <br />332 HSC 25298(b) Failed to comply with temporary closure requirements. <br />This UST system was found to be illegally abandoned. No person shall abandon an UST system without complying <br />with the requirements of HSC 25298. It is unknown what the plans are for the facility. Immediately obtain a permit <br />from the EHD to temporarily close this UST system. A "Failure to Obtain a Permit" penalty applies. <br />This is a Class I violation. <br />Received by Inspector: Phone: Date: <br />(initial): FATINAH ZAREEF, REHS 1 (209) 953-7311 06/12/2015 <br />Page 6 of 7 <br />