Laserfiche WebLink
Reliable Petroleum Services, Inc. <br />Page 2- of 3 <br />T 2:87 TANK <br />LEAK TEST METHOD <br />PRODUCT CODE <br />2 <br />— — — — — — — — — — — — <br />THERMAL COEFF :.000700 <br />TEST ON DATE : ALL TANK <br />TANK DIAMETER <br />92.00 <br />JUL 1, 2009 <br />TANK PROFILE <br />t PT <br />START TIME : DISABLED <br />FULL VOL <br />8275 <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />FLOAT SIZE: 4.0 IN. <br />TST EARLY STOP:DISABLED <br />WATER WARNING <br />2.0 <br />LEAK TEST REPORT FORMAT <br />HIGH WATER LIMIT: <br />3.0 <br />NORMAL <br />MAX OR LABEL VOL: <br />8275 <br />OVERFILL LIMIT <br />90% <br />7447 <br />HIGH PRODUCT <br />95% <br />7861 <br />DELIVERY LIMIT <br />3% <br />277 <br />LOW PRODUCT <br />300 <br />LEAK ALARM LIMIT: <br />99 <br />SUDDEN LOSS LIMIT: <br />99 <br />LIQUID SENSOR SETUP <br />TANK TILT <br />0.00 <br />— — — — — — — — — — — — <br />PROBE OFFSET <br />0.00 <br />L 1:87 STP SUMP <br />TRI—STATE (SINGLE FLOAT) <br />SIPHON MANIFOLDED <br />TANKS <br />CATEGORY : STP SUMP <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />L 2:91 STP SUMP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />LEAK MIN PERIODIC: <br />0% <br />0 <br />L 3:ANNULAR <br />LEAK MIN ANNUAL <br />0yo <br />TRI—STATE (SINGLE FLOAT) <br />0 <br />CATEGORY : ANNULAR SPACE <br />i <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY I MIN <br />PUMP THRESHOLD 10.00% <br />OUTPUT RELAY SETUP <br />— — — — — — — — — — — — <br />R 1:87 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L 1:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />R 2:91 STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />SOFTWARE REVISION LEVEL <br />VERSION 129.02 <br />SOFTWARE# 346129-100—C <br />CREATED — 09.07.01.16.45 <br />NO SOFTWARE MODULE <br />SYSTEM FEATURES: <br />PERIODIC IN—TANK TESTS <br />ANNUAL IN—TANK TESTS <br />ALARM HISTORY REPORT <br />---- IN—TANK ALARM <br />T 1:91 TANK <br />SETUP DATA WARNING <br />JUL 1, 2009 9:34 All <br />LOW PRODUCT ALARM <br />JUL 24, 2012 4:07 PH <br />FEB 10, 2012 12:01 PH <br />DEC 23, 2011 4:47 PH <br />INVALID FUEL LEVEL <br />AUG 24, 2012 10:28 AM <br />JUN 12, 2012 10:03 AM <br />FEB 27, 2012 11:54 AM <br />PROBE OUT <br />JAN 21, 2011 3:31 PH <br />JUL 1, 2009 9:39 AM <br />JUL 1, 2009 8:17 AM <br />DELIVERY NEEDED <br />FEB 18, 2011 7:19 PH <br />JAN 28, 2011 11:48 AM <br />LOW TEMP WARNING <br />JAN 21. 2011 3:32 PH <br />Ai_': � j ,' <br />x x x x x END X � * * x <br />