My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
1856
>
2300 - Underground Storage Tank Program
>
PR0231069
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2023 11:45:51 AM
Creation date
6/3/2020 9:44:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231069
PE
2361
FACILITY_ID
FA0001909
FACILITY_NAME
STOP N SHOP
STREET_NUMBER
1856
Direction
W
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
123-191-02
CURRENT_STATUS
01
SITE_LOCATION
1856 W COUNTRY CLUB BLVD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231069_1856 W COUNTRY CLUB_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- Pae 1 of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-z. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) <br /> BU ESS NAME(Same as Facility Name or DBA) 3. <br /> coINJtj-r vr> FtbD V f.l. <br /> BUSINESS SITE ADDRESS 103. CITY s o J r l 104. <br /> US(, CooNom-Y J'b &i--c> ceR^C7�1 <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> __bb the a ui ment manufacturers'instructions,or annually,whichever is more frequent:Such work must be performed by_qualified personnel:.[23 ccR§2632,2634.2638,2641] <br /> .....----q._.p....__................ .._..._._...._...- .._..__........__.. __ <br /> MONITORING EQUIPMENT IS SERVICED 1.ANNUALLY ❑ 99.OTHER S eci fy) a90-3490-3a.( p : 490-36. <br /> III. MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ['} 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,26341 4904. <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br /> that apply) <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 49-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,2634] <br /> SECONDARY CONTAINMENT IS:� /X a.DRY [Ib.LIQUID FILLED El c.PRESSURIZED _' (❑ d.UNDER VACUUM 490-6. <br /> V <br /> PANEL MANUFACTURER: tkb�`- O-T 490-7. MODEL#: L4 TV-1;> 'C 490-8. <br /> LEAK SENSOR MANUFACTURER 490-9. MODEL#(S): aZ 490-10. <br /> ❑ 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§2643] <br /> 1/r 490-12. 490-13. <br /> PANEL MANUFACTURER: ay���Fc-=is�d��s- MODEL#: <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> 490-18. <br /> PROGRAMMED TESTS: El a.0.1 g.p.h.__...-.__........_[I b.0:2 g.p.h. El C_OTHER(Specify): _. 490.19. <br /> _..... ....__......_.-_....---........_.._-................�....__._...... <br /> 490-20. <br /> El3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.1] <br /> -._......_..-......_...._ ._.....----.......--......-_....._-.......__.............-...._.........._...._....-......_................-............-...........�......__.-.........-.....-...-............-_........_-...........-................-._.............-_.....---....._... <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING MTG [z3 CCR§2645] TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 49421. <br /> ( ) 49-22,-- <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.1] 490-23. <br /> 490.24. <br /> TEST FREQUENCY: ❑ a.ANNUALLY -❑ b_BIENNIALLY ❑ c.OTHER (�cify)_ 490-25__, <br /> ... . 490.26. <br /> ❑ 99.OTHER(Specify): 490-27. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) th,tea�tl) <br /> 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-21. <br /> [§26CCR 36] SECONDARY CONTAINMENT IS: R a.DRY [Ib.LIQUID FILLED Elc.PRESSURIZED Eld.UNDER VACUUM 490-29. <br /> PANEL MANUFACTURER: VP_1:zL _ iZOU490-30. MODEL#: TLS TC-0 490-31. <br /> LEAK SENSOR MANUFACTURER: V eEvix- Zoo r 490-32. MODEL#(S): ZU 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. f a.YES ❑ b.NO 490-31. <br /> - ...._ .....__...........�_....._...-_...._.....- -...... ...........-..._.... -..........-...._ -...........-....._._.-..._....._._...........- ........___....._....-...._.....--..... -......-- _--_ <br /> 2.MEANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 49-36• <br /> CH <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S): 490-37. MODEL#(S): FX (NA 490.38. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490-39. <br /> ELLD MANUFACTURER(S): 490-40. MODEL#(S): 490.41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49042. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-44. <br /> _ -_.....-....-......_.....-- ....----.....---......._-....._-..._._..-..........-..........._..._..._.....-..................._... ........-.................-.. -...... - .._..._-.__...._ ............._-._._....._-..........._._-..._........._-._._..___. <br /> ❑ 4.PIPE INTEGRITY TESTING. 490 as. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(. Pe fy)S ci a90 46. <br /> �._..._-_......_.-..........__..........-_...._._-.._.__.-.....-- -..........--._...._._..-._..............-._................_._............ <br /> -_.._....__.-..._......._..-_... <br /> ❑ 5.VISUAL PIPE MONITORING. ago-as. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED' 490-a9. <br /> _. _-.._..._....-.._....._---.....__-_.....-......._-._.....----"--_-....._..-........._-......__.� . <br /> •Allowed for monitoring of unburied emergenncy generator fuel pi iP ng only ep r HSC•.§25281.5(ti�i3�„-,,,,,.,,-.....,... <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.123 CCR§2636(a)(3)] 49480. <br /> --...._..-..........-.._.......--....._...- . <br /> ................---............_._._._.........--..._..........._........,_....-..__... _..... .....�__...._._-......_-......_.._ _...-...._._ .........�_.....__.- ..._.-_. ...... <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490 St <br /> .........-.............._-.._.._.....__..._..........._......_.............-_........----......---....._....-............- .......__.-_._....._._-_.._.....__.._..................-._......___.._.....--._......_..._ .....--..... .... <br /> ago-sz. <br /> ❑ 99.OTHER(Specify) 490-53. <br /> UPCF UST-D(12/2007)-1/4 www.unidoes.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.