Laserfiche WebLink
4 <br />• <br />- A & A TANK TESTING <br />i <br />. <br />5630 DISTRICT BLVD., SUITE 103 <br />BAKERSFIELD,CALIFORNIA 93313 <br />TANK OWNER'S NAME <br />MOBIL OIL <br />CORPORATION DATE OF TEST 27-Jul-88 <br />, <br />ADDRESS OF TANK <br />3202 W. HAMMER LANE, STOCKTON, CA PRODUCT IN <br />TANK UNLEADED <br />LOC 1 STN FD <br />10-992 <br />NOMINAL CAPACITY -10000 <br />f#f#t###f#t#f###}f#}#}{##{#f#t#}}f}#fff##ffft#######f###}###########f##f#f#tt#}f#t#}f##f####{}{{f#f}#}###ftf#}#t}f##f###f####f#####f <br />TYPE OF PRODUCT <br />GASOLINE <br />THERMAL SENSOR BOX READING <br />19635 <br />TANK DIAMET 92 <br />TOTAL TANK QUANTITY <br />9,758 <br />TEMPERATURE BETWEEN (IN Fl <br />62/83 <br />OBSERVED API GRAVITY <br />56 <br />DIGITS PER DEGREE IN RANGE <br />SAMPLE TEMP. (IN F) <br />84 <br />OF EXPECTED CHANGE <br />308 <br />}#}}f#f#f######f##tf#t#f}}}t##f#f###}##{{{{{{#{{#{{{{f#f{{{f######}##fff##f#fttf}#}#tt#f#fft}f}t###t}###f##}#####ff##}#t#f#ff#ff#f#f# <br />TEMP. IN TANK AFTER <br />CIRCULATION (IN <br />F) 82.4 DIFFERENCE <br />2 <br />R E C I P R 0 C A.L <br />1514 <br />PAGE NUMBER 60 <br />TANK QUANTITY <br />9,758 DIVIDED BY RECIPROCAL 1514 = COEFFICIENT OF EXPANSION <br />6.445178 <br />COEFF. OF EXPANSION <br />6.445178 <br />DIVIDED BY DIGITS 308 = A FACTOR <br />FOR THIS TEST <br />0.0209 <br />###ff###f}###}f###fff#t#}f#}}#####fff##fff#}##}}####ft#f##f##tt}###t######}}###ftffff{{{{{{{{{fffffftff}#########f#ff##f#t##ttt###### <br />HYDROSTATIC <br />VOLUME <br />TEMPERATURE <br />NET ACCUM. <br />PRESSURE <br />MEASUREMENT <br />COMPENSATION <br />VOLUME CHANGE <br />CONTROL <br />CHANGE <br />VOLUME <br />THERMAL <br />REPLACED - <br />SENSOR <br />BEGIN RESTORED BEFORE AFTER RECOVERED + <br />READING CHANGE <br />COMP. <br />TEMP AD3 <br />BASE READING <br />42 <br />19635 . <br />START HIL 1. <br />43.1 ` 42 <br />230 300 0.070 <br />19635 0 <br />6.000 <br />0.070 <br />2. <br />43.2 42 <br />300 380 0.080 <br />19637 2 <br />0.042 <br />0.038 <br />3. <br />42.9 42 <br />380 435 0.055 <br />19648 11 <br />0.230 <br />-0.175 <br />4. <br />41.2 42 <br />435 395 -0.040 <br />19648 0 <br />0.000 <br />-0.040 <br />5. <br />43.4 42 <br />395 485 0.090 <br />19652 4 <br />0.084 <br />0.006 <br />6. <br />43.0 42 <br />485 550 0.065 <br />19656 4 <br />0.084 <br />-0.019 <br />7. <br />43.1 42 <br />550 630 0.080 <br />19663 7 <br />0.146 <br />-0.066 <br />8. <br />43.1 42 <br />630 700 0.070 <br />19667 4 <br />0.084 <br />-0.014 <br />9. <br />10. <br />11. <br />12. <br />BASE READING <br />12.0 <br />19667 <br />START L/L 1. <br />14.2 12.0 <br />25 165 0.140 <br />19671 4 <br />0.084 <br />0.056 <br />2. <br />13.8 12.0 <br />165 275 0.110 <br />19677 6 <br />0.125 <br />-0.015 -0.015 <br />3. <br />13.8 12.0 <br />275 385 0.110 <br />19682 5 <br />0.105 <br />0.005 -0.010 <br />4. <br />13.8 12.0 <br />385 495 0.110 <br />19688 6 <br />0.125 <br />-0.015 -0.025 <br />5. <br />13.8 12.0 <br />495 605 0.110 <br />19693 5 <br />0.105 <br />0.005 -0.020 <br />TEST RESULTS -0.020 <br />TECHNICIAN 114 <br />THE TIME OF TEST, THIS SYSTEM <br />i u .,, <br />, TS N F P A REQUIREMENTS FOR A <br />CERTIFICATION 414811422 <br />TIGHT SYSTEM. <br />NUMBER <br />THERMAL SENSOR <br />SERIAL NUMBER <br />1348 <br />