Laserfiche WebLink
D. Alternate const A for new underground storage tanks contain gator vehicles fuel [Section 26331. <br /> (1) monitoring and response plan [Section 26343. <br /> (2) Underground storage tank composed of.... <br /> (a) Fiberglass reinforced plastic. <br /> (b) Cathodicatly protected steel. <br /> (c) Steel clad with fiberglass reinforced plastic. <br /> _ (d) other material that complies with section 2631 and 2632. <br /> V (3) Floor of teak interception and detection system constructed on a firm base and sloped to a <br /> collection sump (use of membrane liners comply with section 2631 (d) (6) requirements.) <br /> (4) Access casings installed in the collection sump of the secondary containment system with <br /> backfill in the interstitial space. The access casing shall meet all of the following: <br /> Designed and installed to allow the liquid to flow into the casing. <br /> Le/ Sized to allow removal of collected liquid and able to withstand all anticipated applied <br /> stresses. <br /> Constructed of material that will not be structurally weakened. <br /> Screened along entire vertical zone of permeable material. <br /> Capable of preventing leakage of any hazardous substance from the casing. <br /> 1 Extend to the ground surface and covered with a Locked waterproof cap. <br /> Capable of <br /> meeting S.J: Co. PHS-END Well, Standards. <br /> Leak interception and detection system shalt prevent the leaked hazardous substance from <br /> entering ground water. <br /> 14. INTERSTITIAL SPACE MONITORING <br /> A. visual monitoring [Section 2632 Cc) (1)J <br /> (a) Exterior surface and floor beneath tank monitored by direct viewing <br /> (b) Daily visual inspections <br /> %Z Cc) liquid level in tank to be recorded at time of inspection <br /> (d) If liquid observed around or beneath primary tank, owner will determine if an unauthorized release <br /> has occurred. <br /> e. Mechanical or electronic monitoring [Section 2632 (c) (2)) <br /> (a) Continuous monitoring system connected to an audible and visual alarm system. <br /> Monitoring equipment to be installed <br /> Manufacturer: - e_'— <br /> Model Number: <br /> Sensor Type: _ vapor Liquid _ Both. <br /> Sensor/Panel specifications. <br /> v <br /> Location(s) for sensors: <br /> Tank: !NT=R;=!AL—Piping: �1 <br /> :__..._.. <br /> Dispenser: D <br /> C. Monitoring and response plan submitted [Section 2632 (d) (1) t2)). <br /> 15. is Any special accessories, fittings, coatings, or Linings not inherent within the initial design of the 10 tank or . <br /> doubbtte-wall UST. [Section 2631 (b)] <br /> V/ A. Approved by a nationally recognized independent testing organization. <br /> B. Demonstration of integrity with the primary and/or secondary containment. <br /> 6 <br />