My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2004-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 2:36:32 PM
Creation date
6/3/2020 9:45:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2007
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2004-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
275
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />` UCSB04N — SS#2705448 <br />4. TANK ANNULAR TESTING <br />Page 2 of 7 <br />Test Method Developed By: <br />❑ Tank Manufacturer <br />N Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Used: <br />❑ Pressure <br />N Vacuum <br />❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: 4" DUAL GAUGE (VAC) <br />Equipment Resolution: <br />ME <br />MtFromTesting?l <br />Tank # 87 <br />Tank # 91 <br />Tank #DIESEL <br />Tank # <br />❑ Yes N No <br />❑ Yes N No <br />❑ Yes N No <br />❑ Yes ❑ No <br />Tank Capacity: <br />10,000 <br />10,000 <br />10,000 <br />Tank Material: <br />FIBERGLASS <br />FIBERGLASS <br />FIBERGLASS <br />Tank Manufacturer: <br />XERXES <br />XERXES <br />XERXES <br />Product Stored: <br />87 <br />91 <br />DIESEL <br />Wait time between applying <br />pressure/vacuum/water and <br />15 MINUTES <br />15 MINUTES <br />15 MINUTES <br />starting test: <br />Test Start Time: <br />8:00 <br />8:10 <br />10:00 <br />Initial Reading (Rj): <br />10 Hg <br />10 Hg <br />10 Hg <br />Test End Time: <br />9:00 <br />9:10 <br />11:00 <br />Final Reading (RF): <br />10 Hg <br />10 Hg <br />10 Hg <br />Test Duration: <br />1 HOUR <br />1 HOUR <br />1 HOUR <br />Change in Reading (RF-Rj): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />0 <br />0 <br />0 <br />Was sensor removed for testing? ❑ Yes N No ❑ NA ❑ Yes N No ❑ NA ❑ Yes N No ❑NA ❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and N yes ❑ No ❑ NA N Yes ❑ No ❑ NA N Yes ❑ No ❑NA ❑ Yes ❑ No ❑ NA <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.