Laserfiche WebLink
SAN JOAQUIN COUNTY is <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.smgov.or-q/ehd/unitiii.html <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 02/16/11 <br /> Facility Address: 3202 W Hammer Lane Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification Underground Storage Tank Inspection <br /> 13. The Bravo box float and chains in the 1 and 7 sumps failed to stop the flow of product at the <br /> dispenser when tested. All monitoring equipment shall be maintained to activate an audible and visual <br /> alarm or stop the flow of product at the dispenser when it detects a leak. The service technician cleaned <br /> and adjusted the float and chain devices and verified functionality. <br /> 18. The 87 octane product direct-bury spill container failed when tested. All spill containers shall have a <br /> minimum capacity of five gallons and be capable of containing a spill or overfill until it is detected or <br /> cleaned up. Immediately discontinue deposition of petroleum into this tank until the component is <br /> repaired or replaced by a properly licensed, trained, and certified contractor under permit and inspection <br /> of the EHD. If the spill container can't be replaced immediately, there is a possibility that the 87 product <br /> UST system may be red tagged to prevent fuel inputs. The 87 tank currently contains 3535 gallons. <br /> 23d. The designated operator employee training for all facility employees was not performed. The <br /> designated operator shall train facility employees for which he or she is responsible in the proper <br /> operation and maintenance of the UST system once every 12 months. The training shall include, but is <br /> not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br /> Ensure that employees have been trained by the designated operator, maintain the list on site, and <br /> submit a copy of the training records to the EHD by March 16, 2011. <br /> Notes <br /> 1. Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by March 16, 2011. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE($122). <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TI AT D'S CURRENT HOURLY RATE. <br /> EHDInsp or: Received By: Title: <br /> EHD 23 -003 Rev 08/10/10 CONTINUAT FORM <br />