COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7i] <br />Eil <br />6. Verify that the water level will not cover electrical threaded connections before water <br />testing. If the water will exceed threaded connections to the dispenser conduit seal -off one <br />must ensure no water will enter through that point. This assumes that the conduit threaded <br />connections are not liquid tight. Visual testing only allowed on initial installation to pass <br />NO drips leaks are allowed. If outside of sump can not be observed a minimum 5 hour test <br />must be observe with a level drop no greater than 1/8". Alternative testing can be used such <br />as electronic level probe, which can use its accuracy to reduce test time. <br />7. E.g Data collection time Typical 12" x 32" Box and fail rate of .05 GPH <br />Failure, if rate exceeds Resolution/accuracy Data Time <br />0.0030 in 6 minutes Better than .0005" 6 minutes <br />0.0070 in 15 minutes .001 to .002" 15 minutes <br />0.0150 in 30 minutes .002 to .003" 30 minutes <br />8. After the completion of the water test, certify if the test has passed based on the schedule <br />above. If you experience problems contact Bravo for assistance (323) 888-4133. <br />9. Remove water and properly dispose of and manually dry float cup area. Next, remove <br />weight off the float, if applicable, and make sure the chain is properly adjusted as indicated <br />on installation maintenance instructions. This includes verification of float trip function and <br />proper lead seal crimping to prevent future tampering. To adjust chain, refer to Bravo <br />Installation Instructions page 7 of B2000 Shallow Box and page 6 of the B-8000 Deep Box. <br />10. NOTE: If Local Jurisdictions have high requirements than these please use their test <br />protocols. <br />Thank You, <br />Don Mukai P.E. <br />Bravo Engineering <br />f:Aengineering\winwordyDocumentOut\Doc01-06.doc <br />