My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3202
>
2300 - Underground Storage Tank Program
>
PR0231129
>
COMPLIANCE INFO_2008-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2021 4:28:20 PM
Creation date
6/3/2020 9:45:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2011
RECORD_ID
PR0231129
PE
2361
FACILITY_ID
FA0001817
FACILITY_NAME
7-ELEVEN INC #35355
STREET_NUMBER
3202
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3202 W Hammer Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231129_3202 W HAMMER_2008-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
362
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT%RING SYSTEM CERTISCATION <br /> MAKE / MODEL OF MONITORING SYSTEM: <br /> CERTIFICATION / TEST DATE: November 4, 2011 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#2369/Store#35355 Name 7-Eleven, Inc <br /> Address 3202 W.Hammer Lane,Stockton,CA 95209 Address P.O.Box 711, Dallas,TX 75221 <br /> Phone# 209-957-2900 Phone# 805-523-2949 <br /> Contact Stephen Boyd Contact Stephen Boyd <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified November 4,2011 Lic# 617238 A, B,Haz <br /> Inspector Garrett Backus Contact Dulcinea Covan <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to indicate equipment inspected/serviced) <br /> 131: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-91 <br /> ■ In-Tank Gauging Probe Model: 0847390-107 ■ In-Tank Gauging Probe Model: 0847390-107 <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ■ Annular Space or Vault Sensor Model: 0794390-409 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill I High-Level Sensor Model: ❑ Tank Overfill I High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Diesel Tank#4 (Product): _ <br /> ■ In-Tank Gauging Probe Model: 0847390-107 ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-409 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> 132: DISPENSERS/UDC's <br /> Dispenser#: 1/2 Dispenser#: 3/4 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5/6 Dispenser#: 7/8 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> GWALTON <br /> Signature: I/ ` v ENGINEiEnING� INC. �- <br /> Technician/Cert M Jim Cossey/#A22353/80281671CC Date: November 4, 2011 <br /> ©2011 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.