go REGEI VEE) <br /> Appendix VI FEB 2 2015 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://Www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION ENWRONMENIXi <br /> For Use By All Jurisdictions Within the State of California A r co"O r4c,l I <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7 ELEVEN 35355 Bldg.No.: <br /> Site Address: 3202 W HAMMER LANE City: STOCKTON Zip: 952(19 <br /> Facility Contact Person: MANAGER Contact Phone No.: 209-951-3345 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 2/20/2015 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: TS:-RUL Tank ID: T2:-PUL <br /> In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: mag <br /> ry Annular Space or Vault Sensor. Model: 407 140 Annular Space or Vault Sensor. Model: 407 <br /> Piping Sump/Trench Sensor(s). Model: 208 170 Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: 208 rV Fill Sump Sensor(s). Model: 208 <br /> ry Mechanical Line Leak Detector. Model: FE Petro MLD r Mechanical Line Leak Detector. Model: FE Petro MLD <br /> Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r;Tank Overfill/High-Level Sensor.Model: Flapper rV Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment a and model in Section E on Pae 2). r Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: T3:-Diesel Tank ID: <br /> In-Tank Gauging Probe. Model: mag r In-Tank Gauging Probe. Model: <br /> P Annular Space or Vault Sensor. Model: 407 r Annular Space or Vault Sensor. Model: <br /> �' Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: <br /> rvO Fill Sump Sensor(s). Model: 208 r Fill Sump Sensor(s). Model: <br /> r', Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: r Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(soecifv equipment a and model in Section E on Page 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> rve Dispenser Containment Sensor(s).Model: 208 rV Dispenser Containment Sensor(s).Model: 208 <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> rvO Dispenser Containment Sensor(s).Model: 208 rJ'Dispenser Containment Sensor(s).Model: 208 <br /> PO Shear Valve(s). r;Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). r Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: r Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r, Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). I r Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report;(check all that apply): 'System set- <br /> up Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> � <br /> Certification No.: 842815 License.No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/20/2015 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />