Laserfiche WebLink
MONIT(WING SYSTEM CERTIIWAT10 )' <br /> MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION /TEST DATE: Janua 15, 2015 FEB 2015 <br /> Al. FACILITY A2. OWNER 7WRONMENTAL <br /> Name 7-Eleven Market#23691 Store#35355 Name 7-Eleven, Inc <br /> Address 3202 W.Hammer Lane,Stockton,CA 95209 Address P.O.Box 711,Dallas,TX 75221 <br /> Phone# 209-957-2900 Phone# 805-523-2949 <br /> Contact Stephen Boyd Contact Stephen Boyd <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering,Inc. <br /> Address 1868 E.Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified January 6,2015 Lie# 617238 A,B,Haz <br /> Inspector Contact Veronica Freitas <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to Indicate equipment inspected/serviced) <br /> B7: TANKS <br /> Tank#1 (Product): _Gasoline 87_ Tank#2 (Product): Gasoline 91 <br /> ❑ In-Tank Gauging Probe Model: J ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ■ Annular Space or Vault Sensor Model: 0794390-420 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ■ Fill Sump Sensor(s) Model: 0794380-208 ■ Fill Sump Sensor(s) Model: 0794380-208 <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Diesel Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ■ Fill Sump Sensor(s) Model: 0794380-208 ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> B2: DISPENSERS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 5-6 Dispenser#: 7-8 <br /> ■ Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser# <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is Information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> ,,�a WALTON <br /> Signature: �'""'�— ENGINEERING,INC. <br /> Technician I Cert#: Michael Raymond/B35395 8010985 Date: ,January IS,2015 <br /> 0 2014 Walton Engineering,Inc. <br />